SAFETY PRECAUTIONS 

 

Failure to comply may cause injury or damage! 

 

It is important that the Raz Rehab Shower Chair be properly assembled and 
all adjustments be made carefully. For clarification of any section of this 
manual, contact the Canadian distributor or manufacturer. 

 

Dynamic Health Care Solutions  

 

Raz Design Inc. 

Bolton, Ontario   Canada 

 

 

Toronto, Ontario   Canada 

905.951.8541  /  866.875.2877 

 

416.751.0400   

 

                        

[email protected]

 

 

 

[email protected]

  

 
 

CHAIR CLASSIFICATION BASED ON MAXIMUM USER WEIGHT 

AP / SP / AT 

300 lbs (136 kg) 

 
 

SAFETY INSTRUCTIONS TO CONSIDER FOR RETAIL PURPOSES 

 
 
 

Forward Stability  

The front 5” casters on all models are equipped with dual locks. The step-on lever activates 
both the roll lock and the swivel lock.  

It is essential that the front casters be in the forward 

and outward position before engaging the locks for optimum forward and lateral 
stability. 

 

USERS MAY NOT

 

lean forward as this may cause the chair to tip forward.  

USERS MAY NOT

 

wheel down a ramp (SP, SPHD models) without an attendant who can hold 

onto the chair during the descent. 

 
WHEEL LOCKS ARE NOT BRAKES! Never allow use of the wheel locks to slow down 
the commode when descending inclines as this could cause the chair to tip in the 
direction of travel. 
 

Lateral Stability 

USERS MAY NOT

 

lean over the edge of a Raz Shower Chair as this could cause the chair to tip.

  

USERS MAY NOT

 

attempt to pick up objects from the floor by leaning over and reaching – a 

reacher or assistance from others should be employed

.  

USERS MAY NOT

 

position the Shower Chair on a side slope as this could cause it to tip. 

 
 
 
 

 

Содержание AP

Страница 1: ...Raz Rehab Shower Chairs AP SP Models Dealer Set up and Adjustment Manual A guide to help health care professionals safely set up and adjust Raz Rehab Shower Chairs 20061110...

Страница 2: ...the roll lock and the swivel lock It is essential that the front casters be in the forward and outward position before engaging the locks for optimum forward and lateral stability USERS MAY NOT lean...

Страница 3: ...ully review and test the transfer technique to ensure that the procedure is safe The wheel locks are designed to prevent the self propelling wheels from rotating The dual locks on the casters are desi...

Страница 4: ...lift the backrest up to secure it in place and then place the second coved spacer lower on the backrest tube and then lift the backrest to an upright position 4 Insert an included 2 bolt with a washer...

Страница 5: ...receiver tube to the desired position 3 Line up the through holes in the frame and in the caster extension tubes It may be necessary to rotate the caster extension tube in order to line up the holes T...

Страница 6: ...cking balls do not protrude past the receiver turn the lock nut counter clockwise with wrench to increase grip length If there the wheel is loose and there is too much play in along the axle turn the...

Страница 7: ...teners and other components of the Raz Shower Chair be properly assessed by their dealer at least once per year OPTIONAL ACCESSORY SET UP INSTRUCTIONS Pelvic Support Strap Installation All Models A tw...

Страница 8: ...mechanism will not rotate freely 9 Repeat steps 2 to 8 for other armrest To mount the armrest assembly onto the chair 1 Take the armrest pivot plate and insert the coved spacer over the upper socket...

Страница 9: ...ets to the underside of the seat 4 Place the seat back onto the chair frame nestling the front seat clamps onto the front support tubes 5 Slide jiggle the seat to the desired position 6 Tighten the sc...

Страница 10: ...ter assembly to the desired position 3 Align holes in caster extension with the frame holes and insert the snap pins TIP Locking the caster makes this easier 4 Ensure that the pins are completely thro...

Страница 11: ...tely from 2 to behind the centre line of the back post With the axle plates in the leading position lower edges of plates ahead of upper edges the axles can be adjusted infinitely from 1 in front of t...

Страница 12: ...ls 1 Loosen both straps through the double D ring DD ring on one side of the pelvic strap 2 Adjust by pulling or pushing through the outer end of strap in or out of the DD ring 3 Repeat step 2 for oth...

Страница 13: ...r and lock nut 2 Keeping the upper bolt in place rotate the armrest assembly until the preferred position is reached by aligning one of the 3 holes arranged in a triangle on the armrest pivot plate wi...

Отзывы: