background image

1/20/2015 (3:46 PM) 
2034vx & 2034vxa v6.0.doc 

 

 

3.6.3

 

Place item to be etched inside cabinet. Hold 

Blast Hose (K) in hand (like a pencil).

 

3.6.4

 

By pressing on the Foot Pedal (F), the 

air/abrasive flow starts; by letting off the Foot 
Pedal, the air/abrasive flow stops.

 

3.6.5

 

Depress Foot Pedal (F), holding Blast Hose 

(K) 3

"

 - 4

"

 away from item, use slow sweeping 

motions across image area to be etched.

 

! NOTICE 

Always depressurize the pressure pot when you are 
done blasting for the day.  It is not necessary to do 
this if you are intermittently blasting through out the 
course of the day but should always be done when 
you are done blasting for an extended period of 
time. Instructions for depressurizing the pot are 
covered below. 

3.7

 

Depressurizing the Pressure Pot and 

recycling the abrasive.

 

 

! NOTICE 

Always use the following procedure when you are 
finished blasting or you run out of abrasive. 

! WARNING 

NEVER attempt to open the pressure pot closure 
cap using the Pressure Pot Closure Lever (L).  This 
could cause a sudden UNSAFE release of 
compressed air. The pressure pot opens 
automatically when the pot is depressurized. 

3.7.1

 

After you are done blasting, or you run out of 

abrasive during blasting, keep the dust collector 
turned on and then turn off the Air Inlet Valve (C). 
Then depress the foot pedal until the pot is 
depressurized. When all the air pressure is 
exhausted the pot closure cap will automatically 
open and the abrasive that has collected in the 
bottom of the cabinet will flow back into the pot. 
You can get additional abrasive to fall back into the 
pot by tapping on the outside of the cabinet just 
above the pot.  The pot is now filled again and is 
ready for the next time you blast.

 

! NOTICE 

If for some reason, the pot closure cap does not 
open the pot after the Air Pressure Regulator Gauge 
(H) has reached zero, you can open the closure 
manually by pulling the Pressure Pot Closure Lever 
(L) towards you. NOTE: for safety reasons this 
should never be done unless the Air Pressure 
Regulator Gauge (H) reads zero and the main air 
supply is disconnected. 

 

! WARNING 

Never leave the pot pressurized over night.  If valve 
( C ) is left on and the air compressor supply shuts 
off at night the pot will depressurize and 
automatically open.  When the air compressor 
comes back on the next day, air will run through the 
opened pot and abrasive and dust will blow out 
through the arm holes of the cabinet creating a 
hazardous condition of dust in the air.  

Содержание 2034vx

Страница 1: ... 2034vx 2034vxa Sandcarving System ...

Страница 2: ......

Страница 3: ...1 20 2015 3 46 PM 2034vx 2034vxa v6 0 doc Table of Contents Section 1 Safety Information Section 2 Setup Guide Section 3 Operation Section 4 Maintenance ...

Страница 4: ...ir Pressure Regulator Knob Air Flow Valve Abrasive Flow Valve Air Inlet Valve Foot Switch Valve Footpedal Water Seperator Blast Nozzle Nozzle Holder Air Inlet Valve Quick Disconnect Pressure Pot Closure Lever Blast Hose Union Nut Air Pressure Regulator Gauge U U ...

Страница 5: ...cabinet have seals to help keep dust out but are not explosion proof Do not blast materials that may produce combustible dusts Never use flammable solvents inside the cabinet 1 3 Dusts 1 3 1 Prolonged breathing of dusts produced by blasting media and materials removed by blasting may result in serious respiratory injury or death Health risks may vary with type of abrasive media and materials that ...

Страница 6: ...to follow the procedures in this manual could result in serious injury or death from the sudden release of compressed air NEVER attempt to open the pressure pot closure mechanism using the Pressure Pot Closure Lever L This could cause a sudden UNSAFE release of compressed air The pressure pot opens automatically when the pot is depressurized Never do maintenance on any component of the pressure po...

Страница 7: ...inet 2 3 Cabinet Inspection 2 3 1 Before removing the equipment from the shipping pallet inspect the cabinet for the following 1 External damage to the motor viewing glass power connections switches handles and the pressure pot 2 Check lighting fixtures inside the cabinet to make sure they are tight and have not vibrated loose in shipping NOTICE If there are any external or internal damages to the...

Страница 8: ...7 Foot Petal Connection The foot petal F has a short hose and a long hose with quick disconnect fittings Connect the short hose to quick disconnect fitting on footswitch valve E Connect the long hose to the quick disconnect fitting located between water separator G and the air inlet valve C 2 8 Dust Bag Installation 2 8 1 Remove by pulling rubber plug from bottom hole The rubber plug must be used ...

Страница 9: ...ing 2 11 Adding Abrasive Media The system has been shipped without the abrasive media in the pot Turn the dust collector on place unopened 50lb bag of 150 grit aluminum oxide abrasive into the cabinet Slit the center of the bag open Close the side door and empty the bag using the front armhole access After the dust has cleared remove the bag from the cabinet NOTICE The abrasive media will break do...

Страница 10: ...e pot 2 13 4 Turn on the compressor and let it fully charge with air but DO NOT connect the air hose to the cabinet yet 2 13 5 Air compressors generally have an output regulator and two air pressure gauges One gauge is to indicate the pressure in the tank and the other is the output pressure the customer sets Set the output pressure regulator to 90 psi 2 14 Height Adjustment 2 14 1 The 2034vx Adju...

Страница 11: ...nozzle orifices are used 3 2 Connecting Air to Cabinet 3 2 1 Before connecting the air hose from the compressor to the pot make sure the Air Inlet Valve C is in the OFF position horizontal and the air compressor has been set up according to instructions found in the Rayzist setup guide 3 2 2 Connect the compressor air hose to the Air Inlet Valve Quick Disconnect Plug N but DO NOT turn the air inle...

Страница 12: ...izing the pot the pressure regulator gauge H should read about 30 psi If the gauge has a different reading make an adjustment as follows Unlock the Air Pressure Regulator Knob A by pulling upwards Twist clockwise to increase blast pressure or counter clockwise to decrease blast pressure Set regulator to desired pressure and then press down to lock the knob 3 5 Adjusting Abrasive and Air flow 3 5 1...

Страница 13: ... you are done blasting or you run out of abrasive during blasting keep the dust collector turned on and then turn off the Air Inlet Valve C Then depress the foot pedal until the pot is depressurized When all the air pressure is exhausted the pot closure cap will automatically open and the abrasive that has collected in the bottom of the cabinet will flow back into the pot You can get additional ab...

Страница 14: ...back into the pressure pot 4 2 1 Pinch or twist the bag tightly closed underneath the Ring Clamp then open the clamp by opening the safety lock and then the clamp lever Tie off the bag and discard 4 2 2 Slide a new bag through the Ring Clamp and fold about 3 inches of bag material over the ring Open ring clamp lever and slide bag and ring over PVC disk Close ring lever and secure safety lock 4 2 3...

Страница 15: ...f glass can be sharp and cut through your skin Wear protective gloves when handling the glass 4 5 1 1 The window consists of two 12 x 24 panes of glass the outer double safety laminate replacement not required and the inner 1 8 thick single strength glass The inner single strength glass will get frosted over time and will impair visibility NOTICE 12 x 24 x 1 8 thick single strength window glass ca...

Страница 16: ...cement Always Turn off unplug power from the unit Do not exceed 100 watt bulbs 4 8 4 Dust collector dust bags The dust collector bags are treated with a special non stick liner and should operate with a long life as long as daily and periodic maintenance is followed Replacement is required if any tears develop in the bag allowing dust to bypass collector and exit exhaust vent Periodically check in...

Страница 17: ... Leads Green w Yellow Black White Blower Motor Electrical Connection Box 1 2 EMT From Molded Power Cord with Ground Black White White Black 110 VAC Black White Ground Lug Double Pole 10A Contact Black Green with Yellow Stripe 22mm Lever Action Switch 1 2 EMT From Molded Power Cord with Ground Copper Black Red Red Black 8 4 2 1 3 5 G Motor Leads Green w Yellow Black Red Blower Motor Electrical Conn...

Страница 18: ...er Cord with Ground Black White White Black 110 VAC 1 2 LTNM conduit to actuator N C V V Blue Blue Yellow Yellow White Black AC DCConverter White Black C NC NC to actuator Black White Copper Ground Lug Enclosed Halogen Light Fixture 100w Lamp Double Pole 10 A Contact Black Green Yellow 22mm Lever Action Switch 1 2 LTNM conduit to motor 8 4 2 1 3 5 G Motor Leads Green w Yellow Black Red Blower Moto...

Страница 19: ......

Страница 20: ...RAYZIST COM 800 729 9478 ORDER ONLINE WWW RAYZIST COM STORE ...

Отзывы: