Compass
Standard 22
Operator Manual
Compass Standard 22
and
Standard 22 Compact
45
4102.DOC010102
Edition: February 2015
Error
group
Comment
Error-
code
PCbP
Serial connection of sensor PCB to power PCB faulty
E.L.01
PCbP
Inductive transmission faulty
E.L.02
PCbP
System voltage (B5.5
B5.8) on power PCB faulty
E.L.03
PCbP
Encoder voltage faulty
E.L.04
PCbP
System voltage (B5.1
B5.4) on power PCB faulty
E.L.05
PCbS
Encoder faulty
E.L.06
PCbS
CAN dialogue from gyro card to sensor PCB faulty
E.L.07
PCbS
Follow-up system faulty
E.L.08
PCbC
CAN1 and CAN2 operating voltage faulty
E.L.09
PCbG
Supporting liquid error
E.L.10
PCbG
System voltage (B21.5
B21.8) on outer sphere PCB
faulty
E.L.11
PCbG
Operating voltage 24V faulty
E.L.12
PCbG
Operating voltage 15V faulty
E.L.13
PCbG
Heating operating voltage (B21.1
B21.4) faulty
E.L.14
PCbG
Operating voltage 72V faulty
E.L.15
PCbG
Operating voltage 78V faulty for 400 Hz
E.L.16
PCbG
Gyro supply 55V
eff
faulty
E.L.17
PCbG
Gyro current faulty
E.L.18
PCbG
Pump voltage faulty
E.L.19
PCbG
Pump current faulty
E.L.20
PCbG
Temperature sensor faulty
E.L.21
PCbG
Serial interface MC1 to MC2 faulty
E.L.22
PCbG
CAN interface from sensor PCB to outer sphere PCB
faulty
E.L.23
PCbG
Heating system faulty
E.L.24
Status
Watchdog counter
E.L.25
Status
Power--ON counter
E.L.26
Status
OFF--status counter
E.L.27
Operating condition
Fan failure
C.L.1
Operating condition
Heater failure
C.L.2
Operating condition
Supporting liquid
60
C
C.L.3
Operating condition
Supporting liquid too low
C.L.4
Operating condition
Voltage cut--off
C.L.5