background image

Operator Manual

Compass Standard 22

and

Standard 22 Compact

10

4201.DOC010102

Edition: February 2015

Voltage is supplied to the gyro compass via the Distribution Unit or is directly connected
to the compass itself.

There are separate manuals for the Operator Unit and for the Distribution Unit.

The Quick Settling function is activated via the Operator Unit.

The automatic Speed Error Correction function is available only when a GPS
(NMEA speed and NMEA position) or Pulse Log and a NMEA position is connected.
The relevant data must be supplied via the Distribution Unit.
Manual Speed Error Correction (SEC) is applicable by manual input of speed and
position at an Operator Unit.

Содержание Standard 22 Compact

Страница 1: ...el Germany Tel 49 4 31 30 19 0 Fax 49 4 31 30 19 501 Email Service raykiel com www raytheon anschuetz de 4201 DOC010102 Edition February 2015 Standard 22 Compact GYRO COMPASS and Standard 22 GYRO COMP...

Страница 2: ...re liable to the payment of damages Toute communication ou reproduction de ce document toute exploitation ou communication de son contenu sont interdites sauf autorisation expresse Tout manquement cet...

Страница 3: ...he STD 22 Compass 17 2 1 1 Indications on the compass during the heating stage 18 2 1 2 Indications on the compass during the settling stage 19 2 1 3 Overview of indications digital display during ope...

Страница 4: ...a central Alert Panel Signal Unit Alert Panels or Signal Units must have an acoustical and optical alert indication Make sure that alerts are presented at the conning position Maintenance and repair w...

Страница 5: ...stage The heading information during this settling stage has a reduced accuracy see section 2 1 2 Therefore a continuously supply with 24VDC should be gua rantied There is a reduced accuracy of the co...

Страница 6: ...Operator manual Compass Standard 22 and Standard 22 Compact 4201 DOC10102 IV Edition February 2015 Intentionally left blank...

Страница 7: ...elation to true north This compass provides heading information and status signals to those responsible for heading setting In principle we can distinguish between two different applications for the c...

Страница 8: ...sch tz heading sensors can be connected to the Distribution Unit Outputs 2 x Heading course bus or NMEA designated CHn 1 and CHn 2 1 x Heading course bus Status signals SEC speed error correction Syst...

Страница 9: ...on GPS position GPS speed Pulse Log Direction Pulse Log Status information SEC System Available Quick Settling Option 1x course bus option Additional Output Box 146 103 Step 6 steps degree NMEA option...

Страница 10: ...6 The Compact STD 22 gyro compass consists of the 110 233 NG002 gyro compass the 111 006 gyrosphere Optional features QS Operator Unit 130 606 AC DC converter 121 062 Additional Output Box 146 103 The...

Страница 11: ...2 DOC010102 Edition February 2015 1 1 1 STD 22 Compact Gyro Compass Scope of Supply Gyro compass with outer sphere distilled water and supporting liquid Gyrosphere packed separately Tool and spare par...

Страница 12: ...ship s heading has not been changed between switching off and switching back on The Quick Settling function can not be used During the first setting up installation If the ship s position was changed...

Страница 13: ...with 115 to 230 V AC on the input side and delivers 24 V DC as output voltage with a maximum output power of 240 W see separate manual no 4175 Figure 4 AC DC Converter 121 062 1 1 2 3 Additional Outp...

Страница 14: ...e can be connected directly to the Distribution Unit 259 8 Operator Unit Type 130 626 12 x heading course bus or NMEA 1 x rate of turn 1 x printer RS232 Gyro compass CAN bus Distribution unit Type 138...

Страница 15: ...s on the STD 22 are as follows Heading corrected SEC as NMEA or course bus Data bus CAN Bus Status signals alerts error messages RS 232 for heading and rudder position printer connection Rate of turn...

Страница 16: ...als for the Operator Unit and for the Distribution Unit The Quick Settling function is activated via the Operator Unit The automatic Speed Error Correction function is available only when a GPS NMEA s...

Страница 17: ...1 2 1 STD 22 Gyro Compass Scope of Supply Gyro compass with outer sphere distilled water and supporting liquid Gyrosphere packed separately Tool and spare parts pack Operator and Service manual Operat...

Страница 18: ...015 1 2 2 Optional features for the STD 22 Gyro Compass 1 2 2 1 AC DC converter 121 062 The AC DC converter is supplied with 115 to 230 V AC on the input side and delivers 24 V DC as output voltage wi...

Страница 19: ...3 Technical data The technical data stated here apply equally to the STD 22 Compact Gyro Compass and the STD 22 Gyro Compass 1 3 1 Mechanical data Gyro compass see dimensional drawing 110 D 233 HP005...

Страница 20: ...off for a duration of min 1 hour before Speed Error Correction Automatic correction of a heading related to speed and degree of latitude see also section 2 2 Pulse log input 200 Pulses Nm Pulse log Di...

Страница 21: ...Compact Gyro Compass and the STD 22 Gyro Compass Viewed from above see Figure 8 Digital indication of the following Compass heading Operating status Operating conditions requiring attention Error mes...

Страница 22: ...h buttons B38 and B39 are used to adjust the settings as follows Heading and correction data Settings for functional checks System settings such as data formats or transmission speeds Only authorised...

Страница 23: ...settling phase indicated by an additional dot on the digital display ends 4 hours after switching on Accuracy is now 2 No NMEA Heading and NMEA RoT is displayed output during the settling stage After...

Страница 24: ...ruary 2015 2 1 1 Indications on the compass during the heating stage h heating current temperature approx 30 minutes until a temperature of 45 C has been reached The temperature for the internal follo...

Страница 25: ...MEA RoT is displayed output during the settling stage Continuous light Heading indication still inaccurate For 4 hours after switching on with Quick Settling this is 1 hour Heading indication can be u...

Страница 26: ...splayed during the heating stage Example h 28 8 28 8 C heating stage Settling stage lit up Example The gyro compass is settling in The heading is indicated with an illuminated dot after the last figur...

Страница 27: ...depending on the alignment error a correction depending on a speed error 2 2 1 Alignment error The alignment error A error occurs if the compass was not correctly aligned when it was installed i e whe...

Страница 28: ...tted screws 2 Move switch B37 DIP switch contact 1 to the OPEN position 3 The digital indicator is now indicating ALEr Alignment Error 4 Press button B38 or B39 until the heading you require displays...

Страница 29: ...N OFF ON OPEN B38 B39 OPEN OR 1x 1x 176 9 176 8 176 7 176 6 B38 177 4 177 3 177 2 177 1 If the hold the button down the speed at which it changes will increase DIP switch B 37 OPEN OFF ON DIP switch B...

Страница 30: ...ed heading For automatic speed error correction the ship s speed and the latitude are read into the gyro compass The speed error correction function on the STD22 Compact Gyro Compass Only the automati...

Страница 31: ...e 55 55 Speed 16 Kts 16 Kts Correction value from table 1 7 1 3 True heading 345 1 7 343 3 223 7 1 3 225 Example of a bearing Compass heading 255 Latitude 55 Speed 16 Kts Direction of bearing 135 Corr...

Страница 32: ...3 1 2 8 2 3 1 6 0 8 0 40 0 15 30 45 60 75 90 360 345 330 315 300 285 270 180 165 150 135 120 105 90 180 195 210 225 240 255 270 0 3 0 3 0 3 0 2 0 2 0 1 0 0 7 0 7 0 6 0 4 0 3 0 2 0 1 0 1 0 0 8 0 7 0 6...

Страница 33: ...3 3 2 3 1 2 0 5 5 4 8 4 3 3 5 2 5 1 3 0 5 3 5 1 4 6 3 7 2 6 1 4 0 40 0 15 30 45 60 75 90 360 345 330 315 300 285 270 180 165 150 135 120 105 90 180 195 210 225 240 255 270 4 0 3 8 3 5 2 8 2 0 1 0 0 4...

Страница 34: ...1 5 0 65 0 15 30 45 60 75 90 360 345 330 315 300 285 270 180 165 150 135 120 105 90 180 195 210 225 240 255 270 0 6 0 6 0 5 0 4 0 3 0 2 0 1 2 1 2 1 0 0 9 0 6 0 3 0 1 8 1 7 1 6 1 3 0 9 0 5 0 2 4 2 3 2...

Страница 35: ...7 5 6 1 4 3 2 2 0 9 2 8 9 7 9 6 5 4 6 2 4 0 65 0 15 30 45 60 75 90 360 345 330 315 300 285 270 180 165 150 135 120 105 90 180 195 210 225 240 255 270 7 2 7 0 6 3 5 1 3 6 1 9 0 7 8 7 6 6 8 5 5 3 9 2 0...

Страница 36: ...section 3 1 The flashing decimal point remains until the malfunction has been corrected Decimal point flashes on the digital display unit Please pay special attention when the compass housing is opene...

Страница 37: ...ese are displayed on the compass s digital display after the B38 or B39 buttons have been pressed once 1 to 3 are displayed when button B39 is pressed and 4 6 are displayed when button B38 is pressed...

Страница 38: ...2 4201 DOC010102 Edition February 2015 B38 B39 Condition 4 Examples of conditions flashing OPEN OPEN Condition 1 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 C4 C5 Conditions 1 to 3 C1 C2 C3 Conditions 4 and 5 Fig...

Страница 39: ...ondition is displayed To prevent overheating due to fan failure it is recommended that you do the following Check whether the fan screen is covered and check to see that air can enter the enclosure un...

Страница 40: ...he compass or introduce warm air These measures should be continued until condition 2 stops It is essential that the heater be repaired at the earliest opportunity 3 1 3 Operating condition 3 Supporti...

Страница 41: ...s to be performed by switching off the gyro compass The second section 3 1 4 2 can be performed without switching off the gyro compass but it must be performed very carefully and ideally under calm se...

Страница 42: ...d the distilled water screw Figure 15 2 Fill in distilled water only distilled water from Raytheon Ansch tz part number 148 398 one 230cm3 bottle into the inlet for supporting liquid until the measuri...

Страница 43: ...rd 22 and Standard 22 Compact 37 4102 DOC010102 Edition February 2015 distilled water vent 1 2 3 Figure 15 Immediate measure to fill up with distilled water Level OK at operational temperature appr 50...

Страница 44: ...Operator Manual Compass Standard 22 and Standard 22 Compact 38 4201 DOC010102 Edition February 2015 Dip Stick top Figure 17 Dip Stick levels...

Страница 45: ...must establish the cause possibly a leak and correct the fault If the level of supporting liquid is too low the compass can be destroyed Immediate measure Caution It is strongly recommended to perfor...

Страница 46: ...ch 7 Figure 18 Arrangement of DIP switch Set DIP switch 7 into the upper position the follow up function is stopped Place both hands under 2 of the 4 snap closures and release them by pressing with th...

Страница 47: ...ew sealing rings Place the outer sphere in the compass enclosure Pay attention to the two locking pins on the closure Hold the outer sphere with both hands and guide it under the snap closures on the...

Страница 48: ...oltage cut off supporting liquid temperature does not fall to below 45 C and the voltage supply has been restored the settling stage in indicated again see also section 2 1 1 Compass indications durin...

Страница 49: ...ot displayed and not output to the connected heading receivers An alert signal is indicated on the digital display by means of a flashing Erro for Error flashing OFF flashing OFF occurs only when the...

Страница 50: ...Button B39 Button B38 B37 DIP switch Display Figure 21 Operating elements on the compass after removing the cover The following failed PC boards are possible PCbP power PCB faulty PCbS sensor PCB fau...

Страница 51: ...L 11 PCbG Operating voltage 24V faulty E L 12 PCbG Operating voltage 15V faulty E L 13 PCbG Heating operating voltage B21 1 B21 4 faulty E L 14 PCbG Operating voltage 72V faulty E L 15 PCbG Operating...

Страница 52: ...ff by switching off the power supply Caution Maintenance and repair work should be carried out only by trained and qualified staff who are well versed in national safety regulations After the gyro com...

Страница 53: ...enance Supporting liquid distilled water and Pump Rotor have to be replaced every 18 24 months It is additionally recommended to clean the internal of the outer sphere and the gyro compass Instruction...

Страница 54: ...Operator Manual Compass Standard 22 and Standard 22 Compact 48 4201 DOC010102 Edition February 2015 Intentionally left blank...

Отзывы:

Похожие инструкции для Standard 22 Compact