
Operator Manual
Compass Standard 22
and
Standard 22 Compact
42
4201.DOC010102
Edition: February 2015
3.1.5
Operating condition “Voltage cut-off”
This operating condition is output if the supply voltage is cut off for a short time. The
cut-off period is determined by the fall in supporting liquid temperature. If the
temperature falls below 45
C the compass recognises that the voltage supply has been
switched off in the conventional way.
In the case of a voltage cut-off (supporting liquid temperature does not fall to below
45
C) and the voltage supply has been restored, the settling stage in indicated again
(see also section 2.1.1 “Compass indications during the settling stage”).
Note:
Heading indication can be incorrect. Wait for a complete follow up,
Check voltage supply to the gyro compass!
flashing
Figure 19
:
Digital display for “Voltage cut-off”
If voltage cut-offs occur often, the following checks should be made:
-- check the on--board power supply
or
-- check the the on-board power supply
distribution unit
compass cable
connections
or
-- check the the on--board power supply
AC/DC converter
compass cable
connections