Tertiary Winding System:
Transformers may have a Primary, Secondary and Tertiary winding. Activate the “Tertiary” option,
by touching the check box.
Buttons appear for the additional winding.
And of course, it is also possible to define Tap
positions for this third winding.
When all parameters are complete, press "Go" to create a new Profile.
To generate this transformer as a template press " ->Temp". For more information about templates
see chapter "Working with Templates" on page 76.
Press "Go" to view the screen to fill in the data
from the nameplate of the transformer.
The default Name is the date and the time. This
can be edited.
Select the field you would like to change/edit
and use the screen to change the value or
connect a USB Keyboard to the instrument.
Press “Close” after the name is entered.
Select another field to edit/change.
Instruction Manual Winding Resistance Meter
Type WR100 / WR50 / WR14
Page 74 of 139