1.

 

Safety instructions

 

 

1.

 

Read this leaflet carefully before commencing to install the WARRIOR unit and retain it for future use. 

Installation can only be carried out by suitably qualified personnel. 

2.

 

Check the certification to ensure that the, mains supply and the ambient temperature  present is suitable for 

the unit being installed. 

3.

 

If the WARRIOR unit is to be installed in areas of high vibration, please consult with Raytec. 

4.

 

Externally the WARRIOR unit housing is constructed from marine grade aluminium,  and toughened  glass, 

stainless steel brackets/fasteners and silicone gaskets, internally there are many non metallic  components. 

The end user must ensure that these materials are suitable for the environment the  WARRIOR unit will be 

installed in. 

5.

 

WARRIOR units are designed to withstand marine environments and are tested in accordance with 

IEC60068-2-52. However if the WARRIOR unit is to be installed in a very high corrosive environment 

such as coastal and offshore the following good practice should be followed: 

During installing ensure there are no scratches, chips or defects in external paint surface that 

would allow ingress of water to bare aluminium. If so touch up with suitable paint 

During installation apply an anti corrosive jointing compound to screw threads such as PSU cover 

and external earth points. 

During installation ensure exterior surface of the product is not in direct contact with a dissimilar 

metal such as galvanised steel. If so fit a nylon barrier to prevent galvanic corrosion. 

During maintenance regularly wash down external surface of fitting with clean, fresh water to remove any deposits of 

mineral salts on the exterior surface. 

6.

 

Check certification nameplate on side of floodlight to ascertain type of threaded cable entry on the  luminaire. Select 

suitably certified cable glands and stopper plugs, these must  be parallel thread, have a minimum of 5 full thread 

engagement and be of a medium/fine tolerance to  ISO965-1 and ISO965-3. The cable entry devices selected must 

maintain the IP rating of the luminaire.

 

7.

 

The incoming mains cable should not exceed a temperature rise of 20°C above the ambient  conditions; select 
suitable cable.

 

8.

 

When the unit is installed correctly and in accordance with these installation instructions it will not  harm humans or 

animals.

 

9.

 

Before installing emergency luminaires please check the last charge date of the battery. This is shown  on the 

external product packaging and also on the battery label, alternatively consult date shown on  the declaration 

at the back of this leaflet. If the last charge date was in excess of 3 months (if stored at 5°C to 25°C) or 1 

month (if stored outside this range) from date of installation, please consult  Raytec document 0010-D-00001 

Battery Handling Guide

 

 

 

 

 

 

Replace any cracked protective shield 
Order SPX-BKT-GL from Raytec Ltd 

 

Содержание WARRIOR 24

Страница 1: ...The WARRIOR series of industrial floodlights are specialist devices for use in industrial operating environments The units must be installed in accordance with these instructions and must be installed...

Страница 2: ...eads such as PSU cover and external earth points During installation ensure exterior surface of the product is not in direct contact with a dissimilar metal such as galvanised steel If so fit a nylon...

Страница 3: ...ation Mounting WARRIOR Unit 1 To meet the requirements of certification a MINIMUM of 2 fixing points must be used the fixing points must be suitable for the conditions of use Raytec recommend using M8...

Страница 4: ...epending on the mounting application where possible the cable glands should be kept to the bottom of the floodlight It is very important that the red fibre washers are fitted between the WARRIOR housi...

Страница 5: ...UK Europe Tel 44 0 1670 520055 Americas Tel 1 613 270 9990 www raytecled com 5 Typical wiring diagram standard luminaires Typical wiring diagram emergency luminaires...

Страница 6: ...ck connection 8 Emergency WARRIOR floodlights may have a single green LED fitted adjacent to the incoming cable glands when illuminated the green LED indicates that the emergency system is healthy 9 T...

Страница 7: ...and make the equipment dangerous 3 Isolate the WARRIOR unit from the mains supply and allow to cool before carrying out any maintenance work 4 The unit has 2 independent power supplies in the event t...

Страница 8: ...onsumption Emergency variant 71W max 139W max Power Factor 0 95 Mains Frequency 50 60Hz Inrush Current Ipeak 50 40A t 300 s Total Harmonic Distortion 230Vac full load 10 IP Rating IP66 67 Weight Envir...

Страница 9: ...put is turned on at the source 4 On emergency variants check fuse to ensure it has not blown 5 If LED panel fails to light is it possible to identify if problem is with LED panel or power supply by sw...

Страница 10: ...ing Americas Tel 44 0 1670 520055 sales raytecled com Raytec Ltd Unit 15 Wansbeck Business Park Rotary Parkway Ashington Northumberland NE63 8QW United Kingdom raytecled com Raytec Americas Tel 1 613...

Отзывы: