15
rayteccctv.com
Raytec Global Tel: +44 (0) 1670 520055
Americas Tel: +1 613 270 9990
Installation Steps
1.
VARIO2 is factory set and delivered with a
35˚ beam width.
To alter to 10˚, simply remove
interchangeable lens (ILS). See page 16 for
detailed instructions
To alter to 60˚, replace with other ILS lens
supplied
2.
Mount Illuminator
3.
Connect Illuminator to low voltage input 12-
24V AC/DC (For Vario 16 variants:
24V AC or
DC only
)
4.
Complete configuration, wiring and final
set-up using manual push buttons on the
illuminator or VARIO Remote Controller (VRC)
- VRC is an optional accessory
Photocell
Cable
Breather
Gland
Wiring - six core cable
White & Yellow wires
=
Photocell following contact.
Volt free output. Non polarity sensitive.
Orange & Purple wires
=
Telemetry input Volt free/dry contact or
TTL input
(See Page 17 - Step 4 for more details)
DC
AC
Black wire
-
~
Red wire
+
~
The external cable cannot be replaced. If it is damaged and the customer is unable
to shorten and re-use the cable, the illuminator must not be powered.