22
Step 3: Set up camera, lens, and illumination
•
Check model number to Raytec performance specification to ensure
required distance is achievable;
-
Check unit is set to max power
-
Check orientation of unit and ensure it is pointing in correct direction
-
Check angle of unit (Interchangeable lens) – Too narrow may cause
hot spots and the aperture of the camera lens to close down. Too wide
and there may be insufficient light on scene and light going where it is
not needed.
•
Check the LED status indicators for the status of the illuminator.
Programming mode – LHS Green Solid RHS LED flashes AMBER 1 sec on/off
Operating mode – LHS Green Solid
Status LEDs can be turned off in either mode – check if no LEDs visible.
LHS SOLID GREEN:
Power Applied
LHS FLASHING GREEN: Remote control IR receiver problem
RHS FLASHING AMBER: Indicates unit is in programming mode
RHS SOLID AMBER:
Indicates that a valid command is being received
LHS FLASHING RED:
Voltage supply problem detected
LHS SOLID RED:
Illuminator fault detected
Note: the if there is a voltage supply error, the LHS RED LED will FLASH RED
but extinguish and revert to the standard SOLD GREEN when the correct
voltage has been restored.
The fault indications are non latching
•
Check unit is responding to remote /Manual Control buttons.
If not..
-
Status indicators may be turned off. Turn on with remote or with manual
buttons. This can be done even if programming has been disabled