3
Installation Steps:
1
.
VARIO2 is factory set and delivered with a 35˚
beam width.
To alter to 10˚, simply remove interchangeable
lens (ILS). See page 4 for detailed instructions
To alter to 60˚, replace with other ILS lens
supplied.
2. Mount Illuminator
3. Connect Illuminator to low voltage input 12-24V
AC/DC (For Vario 16 variants : 24V AC or DC only)
4-6. Complete configuration, wiring and final set-up using manual push
buttons on the illuminator or VARIO Remote Controller (VRC)
- VRC is an optional accessory
The external cable cannot be replaced. If it is damaged and the customer
is unable to shorten and re-use the cable, the illuminator must not be
powered.
Wiring – six core cable
White & Yellow wires =
Photocell following contact,
Volt free output, Non polarity sensitive
Orange and Purple Wires =
Telemetry input Volt free / dry contact or
TTL input (see Page 5 and 6 for more detail)
DC
AC
Black Wire -
~
Red Wire
+
~
Photocell
Cable
Breather
Gland