940-M-0003
Page 6
Revision B
5. The unit has one independent power supply, in the event that the power supply needs to
be replaced the cables to the LED and mains terminal block will need to be
disconnected, the four M6 bolts released, then the power supply can then be removed.
Fitting a new power supply is a reversal of the above procedure.
6.
Disposal of packaging, SPARTAN unit and old LED assemblies should be carried out in
accordance with national regulations.
4.TECHNICAL SPECIFICATION
SPARTAN Bulkhead 24
(Standard)
SPARTAN Bulkhead 24
(Emergency)
Input Voltage
110-254V AC or 18-30V AC/18-40V DC
see certification nameplate on product
Consumption
34W max
37W max
Power Factor
>0.95
Mains Frequency
50/60Hz
IP Rating
IP66/67
Weight (std)
5Kg
6Kg
Dimensions
See previous pages for line diagrams
ATEX and IECEx Rating
See below
PROTECTION/CERTIFICATION
CML13ATEX3007 or IEC Ex CML14.0001
II 2 GD Ex em IIC T5 Gb
Ta up to -52
o
C to +55
o
C
II 2 GD Ex em IIC T6 Gb
Ta up to -52
o
C to +48
o
C
Ex tb IIIC T82°C Db
IP66 & IP67
Ta up to -52°C to +55°C
110V to 254V AC ONLY or 18-30V AC/18-40V DC
*Emergency variants restricted to -20
o
C
5.TROUBLE SHOOTING
1. Ensure the two LED boards are correctly wired to terminal block.
White to White: White (marked red/red crimp) to White (marked red/red crimp)
2.
Ensure Mains input is correctly connected.
3.
Ensure Mains Input is turned on at the source
4.
*On emergency variants check fuse to ensure it has not blown
5.
If LED panel fails to light is it possible to identify if problem is with LED panel or power
supply by swapping LED cables to opposite power supply to help identify problem.