This installation guide provides instructions for installing the RAYMAX Infra-Red and 
RAYLUX White-Light WARRIOR series of explosion protected illuminators.

1.  Safety Instructions

2. Installation

3. Maintenance

4.  Technical Specification

5.  Trouble Shooting

Version 4.0

Important information

•  The WARRIOR series of explosion protected illuminators are specialist devices, 

certified for use in specific operating environments.

•  The units must be installed in accord with these instructions, must be correctly 

certified for the specific operating environment and must be installed by suitably 
qualified personnel.

•  If you have any queries about the installation or the certification of the unit – please 

contact Raytec for immediate assistance and advice.

Overview

Содержание RAYMAX WARRIOR

Страница 1: ...ing Version 4 0 Important information The WARRIOR series of explosion protected illuminators are specialist devices certified for use in specific operating environments The units must be installed in...

Страница 2: ...ine grade aluminium and polycarbonate The end user must ensure that these materials are suitable for the atmosphere the WARRIOR unit will be installed in Zone 1 and Zone 2 Hazardous areas 5 The incomi...

Страница 3: ...ng light conditions 3 The WARRIOR illuminator and the mounting bracket is supplied together as a unit The bolts in the side of the housing shall be removed and used to secure the bracket to the WARRIO...

Страница 4: ...LOW GREEN YELLOW Photocell Black ve Red ve N L E Wire the Mains cable into the terminal block Provision has been made for this and identified as the E Earth Ground L Live and N Neutral terminals There...

Страница 5: ...1 mm of the metal of the terminal throat iii All terminal screws used and unused on the WARRIOR terminal block type Bk IECEx SIR 05 0035U terminal block shall be tightened down to between 0 5 Nm and...

Страница 6: ...y must be replaced contact Raytec for assistance 3 It is essential that all WARRIOR units are maintained in accordance with the requirements of the EN60079 17standard Electrical apparatus for explosiv...

Страница 7: ...correctly wired to terminal block Red to Red Black to Black 2 Ensure Mains input is correctly connected Earth Ground to Yellow Green Live to Brown Neutral to Blue 3 Ensure Mains Input is turned on at...

Страница 8: ...8 UK Europe T 44 0 1670 520055 F 44 0 1670 819760 sales rayteccctv com Americas Toll Free T 1 888 505 8335 ussales rayteccctv com www rayteccctv com WII 11 10 1...

Отзывы: