4. Technical Specification

Input Voltage

 

100-254V AC 

 

24V AC/DC 

version available

Consumption

 

60W max

Power Factor

 

>0.95

Mains Frequency

 

50/60Hz

IP Rating

 

66/67

Weight

 

6kg

Dimensions

 

250 x 165 x 145mm

ATEX and IECEx

 

Zone 1 & Zone 2:  

Rating

 

II 2GD Ex emb II

Protection / Certification

IECEx Cert.

Ex emb IIC T4 Gb

Ex t IIIC T103°C  

Db IP66/67

Tamb -20°C to +50°C

ATEX Cert.

II 2 G D

Ex emb IIC T4 Gb

Ex t IIIC T103°C  

Db IP66/67

Ta = -20°C to +50°C

WARRIOR Specification

3. Maintenance

1.

  Isolate the WARRIOR unit from the mains supply and allow to cool before carrying out 

any maintenance work.

2.

  In the unlikely event of the failure of an LED, the assembly must be replaced; contact 

Raytec for assistance. 

3.

  It is essential that all WARRIOR units are maintained in accordance with the requirements 

of  the  EN60079-17standard:  (Electrical  apparatus  for  explosive  gas  atmospheres  – 
other than mines).

4.

 

IMPORTANT.

  No  modifications  are  permitted  to  the  unit,  all  spare  parts  must  be 

purchased  from  the  manufacturer,  unauthorized  modifications  or  spare  parts  will 
invalidate certification. 

5.

 

ELECTROSTATIC CHARGING HAZARD

 - Plastic components may be cleaned with 

water containing a small amount of detergent, followed by a clean water wash. Surplus 
water can be wiped off plastic components, but they should not be wiped or polished 
with a dry cloth to avoid a build-up of static electricity.

6.

  Disposal of packaging, WARRIOR unit and old LED assemblies should be carried out 

in accordance with national regulations.

Содержание RAYMAX WARRIOR

Страница 1: ...ing Version 4 0 Important information The WARRIOR series of explosion protected illuminators are specialist devices certified for use in specific operating environments The units must be installed in...

Страница 2: ...ine grade aluminium and polycarbonate The end user must ensure that these materials are suitable for the atmosphere the WARRIOR unit will be installed in Zone 1 and Zone 2 Hazardous areas 5 The incomi...

Страница 3: ...ng light conditions 3 The WARRIOR illuminator and the mounting bracket is supplied together as a unit The bolts in the side of the housing shall be removed and used to secure the bracket to the WARRIO...

Страница 4: ...LOW GREEN YELLOW Photocell Black ve Red ve N L E Wire the Mains cable into the terminal block Provision has been made for this and identified as the E Earth Ground L Live and N Neutral terminals There...

Страница 5: ...1 mm of the metal of the terminal throat iii All terminal screws used and unused on the WARRIOR terminal block type Bk IECEx SIR 05 0035U terminal block shall be tightened down to between 0 5 Nm and...

Страница 6: ...y must be replaced contact Raytec for assistance 3 It is essential that all WARRIOR units are maintained in accordance with the requirements of the EN60079 17standard Electrical apparatus for explosiv...

Страница 7: ...correctly wired to terminal block Red to Red Black to Black 2 Ensure Mains input is correctly connected Earth Ground to Yellow Green Live to Brown Neutral to Blue 3 Ensure Mains Input is turned on at...

Страница 8: ...8 UK Europe T 44 0 1670 520055 F 44 0 1670 819760 sales rayteccctv com Americas Toll Free T 1 888 505 8335 ussales rayteccctv com www rayteccctv com WII 11 10 1...

Отзывы: