6
4. Technical Specification
Input Voltage
100-254V AC
24V AC/DC
version available
Consumption
60W max
Power Factor
>0.95
Mains Frequency
50/60Hz
IP Rating
66/67
Weight
6kg
Dimensions
250 x 165 x 145mm
ATEX and IECEx
Zone 1 & Zone 2:
Rating
II 2GD Ex emb II
Protection / Certification
IECEx Cert.
Ex emb IIC T4 Gb
Ex t IIIC T103°C
Db IP66/67
Tamb -20°C to +50°C
ATEX Cert.
II 2 G D
Ex emb IIC T4 Gb
Ex t IIIC T103°C
Db IP66/67
Ta = -20°C to +50°C
WARRIOR Specification
3. Maintenance
1.
Isolate the WARRIOR unit from the mains supply and allow to cool before carrying out
any maintenance work.
2.
In the unlikely event of the failure of an LED, the assembly must be replaced; contact
Raytec for assistance.
3.
It is essential that all WARRIOR units are maintained in accordance with the requirements
of the EN60079-17standard: (Electrical apparatus for explosive gas atmospheres –
other than mines).
4.
IMPORTANT.
No modifications are permitted to the unit, all spare parts must be
purchased from the manufacturer, unauthorized modifications or spare parts will
invalidate certification.
5.
ELECTROSTATIC CHARGING HAZARD
- Plastic components may be cleaned with
water containing a small amount of detergent, followed by a clean water wash. Surplus
water can be wiped off plastic components, but they should not be wiped or polished
with a dry cloth to avoid a build-up of static electricity.
6.
Disposal of packaging, WARRIOR unit and old LED assemblies should be carried out
in accordance with national regulations.