1. Safety instructions
1.
Read this leaflet carefully before commencing to install the WARRIOR unit and retain it
for future use. Installation can only be carried out by suitably qualified personnel.
2.
Check the certification to ensure that the mains supply and the ambient temperature
present is suitable for the unit being installed.
3.
If the WARRIOR unit is to be installed in areas of high vibration, please consult Raytec.
4.
The WARRIOR unit housing is constructed from marine grade aluminium and
polycarbonate. The end user must ensure that these materials are suitable for the
atmosphere the WARRIOR unit will be installed in; Zone 1 and Zone 2 Hazardous areas.
5.
The incoming mains cable should not exceed a temperature rise of 61˚C above
the ambient conditions; select suitable cable and cable gland. You must use ATEX
approved cable and glands e.g. M25, for advice on suitable glands and cables please
contact Raytec
Specifications subject to change without notice.
Installation to be carried out by suitable trained and qualified personnel.
!
Isolate mains before
removing cover
Install in a well
ventilated area
Do not continually
stare at lamp
1.5m