The VTS has the following restrictions on its operation:
The minimum delay for the light pulse output is approximately 2μs.
When using the re-
trigger delay, the minimum delay is approximately 5μs.
For pulse widths of less than approximately
70μs, fault
detection does not operate.
The minimum delay
for the trigger output is approximately 2μs.
11.2
Event codes
Event No
Reason
1 to 127
An error has occurred. The error code is given by the event
number.
130
The temperature of the light is too high and operation has
been stopped.
140
The duty cycle is too high.
148
The allowed duty cycle is now normal (that is, after event
149).
149
The allowed duty cycle has been reduced due to high
internal temperature.
170
Self-test has passed.
171
Self-test has failed.
11.3
Error codes
Error No
Reason
Err 1
A parameter value is invalid.
Err 2
Command not recognised.
Err 3
A numeric value is in the wrong format.
Err 4
There is an incorrect number of parameters.
Err 5
This is a warning and not an error. One of the parameters is
out of range. The value of the parameter has been adjusted.
For example, sending an
RT
command with a delay of 0
prompts an 'Err 5' response. The command will be accepted,
and the delay set to the minimum allowed.
Err 6, 12
EEPROM corrupt. The configuration has been cleared.
Err 9, 20
Could not save settings to EEPROM.