background image

HEA

EXCHANGER

JACKET

OTHER

GAS 

TRAIN

SAFETIES

OPERA

TING 

CONTROLS

ASME, National Board Registered, 160 PSI

• HLW Stamp

Heat Exchanger Tubes

• Cupro Nickel

Bronze Headers

Stainless Steel Condensing Heat Exchanger

• U Stamp

Pressure Relief Valve

• 125 PSI

(Mounted on Outlet) (Currently Shipped Loose)
Temperature & Pressure Gauge

Pump - Primary

• 120V, Single-Phase

Indoor/Outdoor Certified

Vent Terminal

• Outdoor
• Through-the-Wall

Fully-Enclosed Controls

Combustible Floor Rated

120V Power Supply with 120V/24V Transformer

On/Off Switch

Programmable Pump Time Delay, Single-Phase

• Included in TempTracker Mod Controller

Terminal Block Connections

• Enable / Disable

(Front mounted)

• External Interlocks

• 0-10 VDC Setpoint/Direct Drive Input

LCD diagnostic display with 16-Event History (2x20 character display, reads in plain English)

Status Display Lights (4)

Temperature Controller with 3 Water Sensors

• TempTracker Mod 

Multiple Heater Controller

• TempTracker Mod+, up to 16 heaters

Hot Surface Ignition System

• 1-try
• 3-try

High/Low Gas Pressure Switches
Blocked Vent and Air Pressure Switches

High Limit Switch

• Manual Reset, Fixed

• Manual Reset, Adjustable
• Automatic Reset, Adjustable (Shipped Loose)

Low Water Cut-Off, 24V

• With Manual Reset and Test Buttons

Flow Switch

Combination Gas Valve

Combustion Air Blower

Additional Safety Valve

• Motorized (externally mounted)
• Solenoid (externally mounted)

CSA-Certified Efficiency

• 97% at Full Fire

Air Filter

TruSeal Direct-Vent Ready

PVC Vent Adapter Option D-32 (Factory installed only)
Alarm System
CSD-1 / GE GAP Control System
Low NOx

• Meets all current requirements

Cold Water Run - Variable Speed Pump

• Prevents condensation in primary heat exchanger

WHP

= Standard       

 

= Optional

Raypak, Inc.

•  2151 Eastman Avenue, Oxnard, CA 93030 • phone: (805) 278-5300 • fax: (800) 872-8725 • www.raypak.com

Cat. No. 6200.12-E   Effective 4-1-11    Replaces 1-1-11 

6200.12-E_XTherm Brochure 8 page  3/29/11  10:58 AM  Page 1

Содержание Xtherm 1505

Страница 1: ...Can be vented with PVC pipe...

Страница 2: ...ation in the primary heat exchanger Raypak s evaporator system collects and re evaporates condensate which may form during initial start up Simplicity The Raypak XTherm will precisely heat your pool U...

Страница 3: ...us inlet water temperature 12 Cold Water Run Pump The XTherm comes factory equipped with a built in Cold Water Run system This advanced water control system keeps the inlet water temperature to the pr...

Страница 4: ...be drawn from inside the heater through screened plenum openings See photo above right 4 Gas Inlet The XTherm will operate at 100 full rate with gas pressures as low as 4 0 w c 5 Water Outlet 6 Water...

Страница 5: ...ce Minimum Do not install on carpeting Note Local codes may require increased clearances Heater Side Model Pool Heater Output Efficiency MBTUH Input MBTUH 1005 999 969 97 1505 1500 1455 97 2005 1999 1...

Страница 6: ...is based on maintaining an indoor swimming pool at 80 F for 6 months of the year and using a fuel cost of 1 00 per therm How to use the table below 1 Select the desired temperature of the pool water 2...

Страница 7: ...comes equipped with a microprocessor controlled diagnostic control center that displays its information on a 2x20 character LCD display in plain English This control monitors system safeties ignition...

Страница 8: ...Display Lights 4 Temperature Controller with 3 Water Sensors TempTracker Mod Multiple Heater Controller TempTracker Mod up to 16 heaters Hot Surface Ignition System 1 try 3 try High Low Gas Pressure S...

Отзывы: