background image

1. Low Voltage Wiring Terminal

Up front and easy to get to. Makes sensor wiring and
BMS wiring simple and clean.

2. On Board Diagnostic Center

Factory-mounted  standard  equipment.  Gives
relevant  service  feedback  as  well  as  possible
solutions  to  clear  the  fault. All  in  plain  english,  no
cryptic codes to decipher. The control also stores up
to  16  fault  codes  in  its  history  file  for  the  service
technician to review.

3. TempTracker Mod Controller

Standard  equipment  on  the  XTherm.  This  factory-
mounted  multi-function  control  delivers  precise
temperature  control  with  selectable  mode  displays
that are easy to access and read.

4. Combustion Air Fan

Cast aluminum, non-sparking construction. The state
of  the  art  variable-speed  fan  is  controlled  by  the
TempTracker  Mod  and  works  in  smooth  harmony
with the main gas valve.

5. Dungs Gas Valve

The  XTherm  uses  a  state-of-the-art  main  gas  valve
manufactured in Germany.  This precision gas valve
works in perfect unison with the combustion air fan.
The result is silky smooth light-offs.

6. Flow Switch 

Monitors water flow and provides safe shut down if
water flow drops below the minimum required.

7. Vent Pressure Switch

Monitors vent pressure and provides safe shut down
if back pressure is excessive.

8. Gas Inlet

The XTherm will operate at 100% full rate with gas
pressures as low as 4.0”w.c.

9. Water Outlet

10. Heater Pump

Sometimes  referred  to  as  the  primary  pump.  This
fixed speed pump keeps flow constant through the
primary heat exchanger.

11. Water Inlet

The XTherm can accept 50°F continuous inlet water
temperature.

12. Cold Water Run Pump

The XTherm comes factory equipped with a built in
Cold Water Run system.  This advanced water control
system  keeps  the  inlet  water  temperature  to  the
primary heat exchanger above 120°F, regardless of
the incoming water temperature.  It constantly self
adjusts and regulates the incoming water flow while
still  maintaining  a  constant       

Δ

T  in  the  heat

exchanger.

13. Flue Outlet

The  stainless  steel  flue  outlet  is  compatible  with
AL29-4C. PVC or CPVC vent material may be used in
conjunction  with  the  D-32  vent  option  on  the
XTherm.  Dramatically  cut  your  installation  costs  by
using these non-metallic vent materials.

14. Stainless Steel Secondary Heat Exchanger

Recovers waste heat to boost efficiency up to 97%.
The XTherm utilizes a separate high-grade stainless
steel  heat  exchanger.  This  allows  the  corrosive
combustion  condensate  to  be  collected  safely
without damaging the heater. There is a condensate
disposal connection on the rear of the heater.  The
XTherm is also equipped with a condensate switch
that  will  sense  a  blocked  condensate  drain,  which
protects the heater.

15. Vertical Primary Heat Exchanger

Cylindrical,  multi-pass  heat  exchanger  captures  all
radiant  energy,  eliminating  the  need  for  heavy
refractory.

16. Drain Valve

One of two drain valves located at the bottom of the
heat exchanger. A third drain valve is located on the
secondary heat exchanger. This allows for complete
winterizing and drainage of the heater.

17. Viewing Port

Allows for easy burner inspection.

18. Weather-Proof Jacket

Heavy  gauge  galvanized  steel  with  a  UV-resistant
Polytuf  powder  coat  is  impervious  to  weather  and
corrosion. The Polytuf coating passes the 1000 hour
salt spray test (ASTM B117).

3

6200.12-E_XTherm Brochure 8 page  3/29/11  10:58 AM  Page 4

Содержание Xtherm 1505

Страница 1: ...Can be vented with PVC pipe...

Страница 2: ...ation in the primary heat exchanger Raypak s evaporator system collects and re evaporates condensate which may form during initial start up Simplicity The Raypak XTherm will precisely heat your pool U...

Страница 3: ...us inlet water temperature 12 Cold Water Run Pump The XTherm comes factory equipped with a built in Cold Water Run system This advanced water control system keeps the inlet water temperature to the pr...

Страница 4: ...be drawn from inside the heater through screened plenum openings See photo above right 4 Gas Inlet The XTherm will operate at 100 full rate with gas pressures as low as 4 0 w c 5 Water Outlet 6 Water...

Страница 5: ...ce Minimum Do not install on carpeting Note Local codes may require increased clearances Heater Side Model Pool Heater Output Efficiency MBTUH Input MBTUH 1005 999 969 97 1505 1500 1455 97 2005 1999 1...

Страница 6: ...is based on maintaining an indoor swimming pool at 80 F for 6 months of the year and using a fuel cost of 1 00 per therm How to use the table below 1 Select the desired temperature of the pool water 2...

Страница 7: ...comes equipped with a microprocessor controlled diagnostic control center that displays its information on a 2x20 character LCD display in plain English This control monitors system safeties ignition...

Страница 8: ...Display Lights 4 Temperature Controller with 3 Water Sensors TempTracker Mod Multiple Heater Controller TempTracker Mod up to 16 heaters Hot Surface Ignition System 1 try 3 try High Low Gas Pressure S...

Отзывы: