background image

X

treme Versatility

Can be installed indoor or outdoors!

1

2

3

4

5

6

7

8

9

3

a

2

1. High Voltage Wiring Box

120VAC connections.

2. Removable Air Filter

Provides  easy  access  and  is  easily  removable  for
inspection  and  replacement.  12”x20”high  capacity
filter is rated MERV 8 (95% - 98% arrestance.)

3. Direct Vent Capability

Every  XTherm  is  direct  vent  capable.  By  installing  the
optional vent pipe adapter (D-18) and air plenum plug,
your XTherm is ready for direct vent. This makes it ideal
for storage of pool chemicals in the same room as the
XTherm.  Damaging  chemicals  are  not  in  contact  with
the heat exchanger or combustion chamber.

3a. Outdoor Cover

If your job requires outdoor installation, an optional air

vent plug easily screws on to cover the direct vent air
intake.  The  combustion  air  will  then  be  drawn  from
inside  the  heater  through  screened  plenum  openings.
See photo above right.

4. Gas Inlet

The  XTherm  will  operate  at  100%  full  rate  with  gas
pressures as low as 4.0”w.c.

5. Water Outlet

6. Water Inlet

The XTherm can accept as low as 50°F continuous inlet
water temperature without damage to the primary heat
exchanger.

7. Access Panel to Cold Run Pump

Easily  removable  access  panel  even  when  unit  is

plumbed  in  place.    Provides  full  access  to  inspect  and
service  the  Cold  Run  Pump  system  and  condensate
drain switch.

8. Flue Outlet

The stainless steel flue outlet is compatible with AL29-
4C.  For  a  dramatic  cost  reduction  over  Category  IV
stainless steel, PVC or CPVC vent material may be used
in conjunction with the D-32 vent option.

9. Condensate Drain

3/4”NPT  PVC  connection  for  condensate  removal.
Raypak  offers  optional  condensate  neutralizer  kits  (Z-
12)  that  can  be  plumbed  between  the  heater  and  the
drain.

Internal Air Intake

4

X

treme Versatility

Can be installed indoor or outdoors!

6200.12-E_XTherm Brochure 8 page  3/29/11  10:58 AM  Page 5

Содержание Xtherm 1005

Страница 1: ...Can be vented with PVC pipe ...

Страница 2: ...sation in the primary heat exchanger Raypak s evaporator system collects and re evaporates condensate which may form during initial start up Simplicity The Raypak XTherm will precisely heat your pool Utilizing the latest European technology for the combustion components the optimum fuel air ratio is maintained throughout the entire range of the load tracking operation The XTherm automatically self...

Страница 3: ...ous inlet water temperature 12 Cold Water Run Pump The XTherm comes factory equipped with a built in Cold Water Run system This advanced water control system keeps the inlet water temperature to the primary heat exchanger above 120 F regardless of the incoming water temperature It constantly self adjusts and regulates the incoming water flow while still maintaining a constant ΔT in the heat exchan...

Страница 4: ... be drawn from inside the heater through screened plenum openings See photo above right 4 Gas Inlet The XTherm will operate at 100 full rate with gas pressures as low as 4 0 w c 5 Water Outlet 6 Water Inlet The XTherm can accept as low as 50 F continuous inlet water temperature without damage to the primary heat exchanger 7 Access Panel to Cold Run Pump Easily removable access panel even when unit...

Страница 5: ...ce Minimum Do not install on carpeting Note Local codes may require increased clearances Heater Side Model Pool Heater Output Efficiency MBTUH Input MBTUH 1005 999 969 97 1505 1500 1455 97 2005 1999 1939 97 PHYSICAL DATA 1005 55 1 8 45 47 1 8 36 1 2 1 1 4 6 40 1 16 11 1 2 6 47 1 8 8 1 16 6 1 16 1065 12 10 1505 67 1 8 57 59 1 16 38 1 2 1 1 4 8 52 1 16 12 5 8 8 59 1 8 8 3 16 6 1 16 1234 12 14 2005 8...

Страница 6: ...is based on maintaining an indoor swimming pool at 80ºF for 6 months of the year and using a fuel cost of 1 00 per therm How to use the table below 1 Select the desired temperature of the pool water 2 Determine the mean average temperature of the month in which the pool will be used 3 Subtract the mean temperature from the desired swimming temperature The difference is the temperature rise 4 Calcu...

Страница 7: ...m comes equipped with a microprocessor controlled diagnostic control center that displays its information on a 2x20 character LCD display in plain English This control monitors system safeties ignition faults and system status while storing up to 16 reported faults Raypak s diagnostic center monitors the fault outputs of the Fenwal ignition control converting the Fenwal s fault codes into real Eng...

Страница 8: ... Display Lights 4 Temperature Controller with 3 Water Sensors TempTracker Mod Multiple Heater Controller TempTracker Mod up to 16 heaters Hot Surface Ignition System 1 try 3 try High Low Gas Pressure Switches Blocked Vent and Air Pressure Switches High Limit Switch Manual Reset Fixed Manual Reset Adjustable Automatic Reset Adjustable Shipped Loose Low Water Cut Off 24V With Manual Reset and Test B...

Отзывы: