background image

19

Wiring Diagram

208V/230V 3Ph, 60Hz Models

Содержание Professional Series

Страница 1: ...355ti E HC Heat Pump Pool Spa Heater US C LISTED R NOTE The instructions in this manual are for the use of qualified individuals specially trained and experienced in the installation and maintenance o...

Страница 2: ...2 reflects the following Changes to Installation Considerations on pages 6 7 Hurricane Tie Down Requirements diagram on page 8 Table C on page 14 Wiring diagrams on pages 19 21 Additions None Deletion...

Страница 3: ...4500 MAXIMUM 4500 MAXIMUM 4500 MAXIMUM Free Chlorine PPM 2 to 3 2 to 3 2 to 3 Total Dissolved Solids PPM 3000 MAXIMUM 3000 MAXIMUM 3000 MAXIMUM Free Chlorine MUST NOT EXCEED 5 PPM In salt water chlor...

Страница 4: ...at Cool Operation 11 System Start Up 11 Seasonal Start Up or Annual Check 11 Summer Shutdown 11 Freeze Protection 12 System Drain Down 12 Continuous Pump Operation 12 Maintenance 12 Air Coil Cleaning...

Страница 5: ...d the heat pump pool heater CAUTION Elevated water temperature can be hazardous The U S Consumer Product Safety Commission has these guidelines 1 Spa water temperatures should never exceed 104 F 40 C...

Страница 6: ...ulation of cold discharge air back into the evaporator coil will greatly reduce the unit s heat ing capacity and efficiency This unit features an up flow discharge for quiet operation Air is pulled up...

Страница 7: ...low the control panel for precise power requirements for your unit and for ampacity and over current protection requirements All wiring must be in accordance with the National Electrical Code NFPA No...

Страница 8: ...ONCRETE PAD SEE PAD SPECS UNIT HIGH WIND LOAD RESTRAINT DETAIL 1 SEE HIGH WIND LOAD RESTRAINT DETAIL 1 2 1 2 MIN SPACING TYP 4 VIBRATION ISOLATION PADS TYP EA CORNER COVERED UNIT HEIGHT BETWEEN 37 1 2...

Страница 9: ...ype must be installed at the unit inlet and outlet to facilitate service and cold weather drain down 5 Operate the pump and check the system for leaks Pressure Drop For system pressure drop informatio...

Страница 10: ...key until you see P _S and by pressing the UP or DOWN key you can switch to POL or SPA To Increase the Desired Water Temperature Pool or Spa Mode Push the SET key until you see POL or SPA The pro gra...

Страница 11: ...ountains sprays or other water features to speed cooling NOTE Heating is more efficient during warmer day light hours and cooling is more efficient during cooler night time hours Seasonal Start Up or...

Страница 12: ...r pipes This is also evidence of heat removal from the air When the air is cool with low humidity condensation may not be evident WARNING Shut OFF electricity to the unit before cleaning Freeze Protec...

Страница 13: ...nd heat pump pool heater shut OFF before the water temperature is raised to the desired level you must lengthen the running time of both To do this reset the time clock dial for the longer running tim...

Страница 14: ...tive dSd The suction line temperature sensor is open or may be defective FLO Possible causes The filter is in backwash position The filter pump is stopped The filter is dirty Shortage of water to pool...

Страница 15: ...HECK VALVE CHEMICAL INTRODUCTION WATER OUT TO POOL OR SPA Fig 6 For systems with pumps of less than 2 HP under 80 gpm no external bypass is required Connections are 2 inch unions Plumb the heat pump p...

Страница 16: ...A Fig 7 For systems with pumps of 2 HP or greater over 80 gpm an external bypass is required Adjust the bypass valve to divert a minimum of 40 gpm through the heat pump pool heater Connections are 2 i...

Страница 17: ...Fig 8 Pool Piping for Heat Pump Pool Heater and Gas Pool Heater 17...

Страница 18: ...y Secondary BRANCH MAIN BRANCH MAIN BRANCH MAIN 15 GPM 2 2 15 GPM 2 2 15 GPM 2 2 30 2 2 30 2 2 1 2 30 2 3 45 2 2 45 2 3 45 2 4 60 2 2 1 2 60 2 3 60 2 4 80 2 3 80 2 4 80 2 5 Sizing based on 10 ft sec f...

Страница 19: ...19 Wiring Diagram 208V 230V 3Ph 60Hz Models...

Страница 20: ...Wiring Diagram 460V 3Ph 60 Hz Models 20...

Страница 21: ...21 Wiring Diagram 380V 3Ph 60 Hz Models...

Страница 22: ...until OFF is displayed Wait until a temperature is displayed before beginning the next step 2 Push the SET key until SPA is displayed then push the UP arrow to 104 F Wait until a tempera ture is displ...

Страница 23: ...23...

Страница 24: ...24 Raypak Inc 2151 Eastman Avenue Oxnard CA 93030 805 278 5300 Fax 805 278 5468 Heat Pump Service 1 800 260 2758 Litho in U S A...

Отзывы: