background image

Introduction

This  manual  contains  important  information  on  the

use,  maintenance  and  troubleshooting  of  your  new

heat  pump  pool  heater.  This  unit  must  be  properly

installed,  maintained  and  operated  for  optimal  per-

formance. 

This heat pump pool heater is an extremely efficient,

economical  machine  designed  specifically  for  swim-

ming pool heating. It is similar in design and operation

to a typical residential air conditioning system. The unit

employs a hermetic motor/compressor operating in a

refrigeration cycle to extract heat from ambient air and

deliver it to the circulating pool water.

As with all heat pump pool heaters, compared to other

types  of  heaters  such  as  gas  or  oil-fired,  this  heat

pump  pool  heater  has  lower  heating  capacity  on  a

BTUH/hr basis. As a result, it will be required to oper-

ate longer to accomplish the desired results. It may, at

certain times, operate as much as 24 hours per day.

However, this should not be of concern to the owner,

because the unit is designed to operate continuously.

Even  though  it  may  operate  continuously  for  many

hours, it will still heat the pool with greater economy

than other types of fossil fuel heaters.

Place  a  cover  or  blanket  over  the  pool  at  night  and

other non-use periods. This will keep evaporation, the

cause of main heat loss, to a minimum, and will great-

ly reduce pool heating costs. During warmer weather,

the cover may be required only at night.

Installation Considerations

Situate  the  heat  pump  pool  heater  carefully  to  mini-

mize  installation  costs  while  providing  maximum

efficiency of operation, and to allow adequate service

access, as follows:

•  For  unrestricted  air  intake  and  service  access,

position each side of the unit at least 1 ft (30 cm)

from walls, pipes and other obstructions.

•  Recirculation  of  cold  discharge  air  back  into  the

evaporator coil will greatly reduce the unit’s heat-

ing capacity and efficiency.

•  This unit features an ‘up-flow’ discharge for quiet

operation. Air is pulled up through the evaporator

coil and discharged through the top grill. Allow at

least 5 ft (1.5 m) clearance above the unit for unre-

stricted  air  discharge. 

DO NOT

install  the  unit

under a porch or deck. Refer to Fig. 1.

•  To minimize water piping, locate the unit as close

as possible to the existing pool pump and filter.

If  the  location  of  the  heat  pump  pool  heater  is

below the water line of the pool, the water pres-

sure  switch  might  need  to  be  adjusted  or  an

external water flow switch might be needed.

WARNING:

This pool/spa heat pump pool heater is

an  electromechanical  machine  that  incorporates  a

pressurized  refrigerant  gas  in  a  sealed  system.

ONLY  trained  and  qualified  service  personnel  are

authorized  to  install  or  service  this  equipment.

Without  proper  training  and  knowledge  of  such

equipment, any attempt to install or service the unit

could result in serious injury or even death.

WARNING:

Do not install the unit within 3 ft of

fossil fuel burning heaters. Air intake along the

sides of this heat pump pool heater could disturb

the  combustion  process  of  the  unit,  and  could

cause damage or personal injury.

• Mount the unit on a level, sturdy base, preferably a

concrete slab or blocks. The size of the base should

be at least 3 ft by 3 ft.

• You must install the 4 black rubber sound iso-

lation pads (each 2 inches square) that ship with

the unit. The pads are shipped in a bag with the

unions, gaskets and the I&O manual. Install pads

under the 4 corners of the unit to reduce vibra-

tion and sound transmission to the base.

CAUTION:

The unit’s supporting base must be high

enough to keep it completely free of standing water

at all times.

WARNING:

This unit is designed for outdoor instal-

lation; 

DO NOT

install it in an enclosed area such as

a shed or garage. 

6

Содержание Professional Series

Страница 1: ...355ti E HC Heat Pump Pool Spa Heater US C LISTED R NOTE The instructions in this manual are for the use of qualified individuals specially trained and experienced in the installation and maintenance o...

Страница 2: ...2 reflects the following Changes to Installation Considerations on pages 6 7 Hurricane Tie Down Requirements diagram on page 8 Table C on page 14 Wiring diagrams on pages 19 21 Additions None Deletion...

Страница 3: ...4500 MAXIMUM 4500 MAXIMUM 4500 MAXIMUM Free Chlorine PPM 2 to 3 2 to 3 2 to 3 Total Dissolved Solids PPM 3000 MAXIMUM 3000 MAXIMUM 3000 MAXIMUM Free Chlorine MUST NOT EXCEED 5 PPM In salt water chlor...

Страница 4: ...at Cool Operation 11 System Start Up 11 Seasonal Start Up or Annual Check 11 Summer Shutdown 11 Freeze Protection 12 System Drain Down 12 Continuous Pump Operation 12 Maintenance 12 Air Coil Cleaning...

Страница 5: ...d the heat pump pool heater CAUTION Elevated water temperature can be hazardous The U S Consumer Product Safety Commission has these guidelines 1 Spa water temperatures should never exceed 104 F 40 C...

Страница 6: ...ulation of cold discharge air back into the evaporator coil will greatly reduce the unit s heat ing capacity and efficiency This unit features an up flow discharge for quiet operation Air is pulled up...

Страница 7: ...low the control panel for precise power requirements for your unit and for ampacity and over current protection requirements All wiring must be in accordance with the National Electrical Code NFPA No...

Страница 8: ...ONCRETE PAD SEE PAD SPECS UNIT HIGH WIND LOAD RESTRAINT DETAIL 1 SEE HIGH WIND LOAD RESTRAINT DETAIL 1 2 1 2 MIN SPACING TYP 4 VIBRATION ISOLATION PADS TYP EA CORNER COVERED UNIT HEIGHT BETWEEN 37 1 2...

Страница 9: ...ype must be installed at the unit inlet and outlet to facilitate service and cold weather drain down 5 Operate the pump and check the system for leaks Pressure Drop For system pressure drop informatio...

Страница 10: ...key until you see P _S and by pressing the UP or DOWN key you can switch to POL or SPA To Increase the Desired Water Temperature Pool or Spa Mode Push the SET key until you see POL or SPA The pro gra...

Страница 11: ...ountains sprays or other water features to speed cooling NOTE Heating is more efficient during warmer day light hours and cooling is more efficient during cooler night time hours Seasonal Start Up or...

Страница 12: ...r pipes This is also evidence of heat removal from the air When the air is cool with low humidity condensation may not be evident WARNING Shut OFF electricity to the unit before cleaning Freeze Protec...

Страница 13: ...nd heat pump pool heater shut OFF before the water temperature is raised to the desired level you must lengthen the running time of both To do this reset the time clock dial for the longer running tim...

Страница 14: ...tive dSd The suction line temperature sensor is open or may be defective FLO Possible causes The filter is in backwash position The filter pump is stopped The filter is dirty Shortage of water to pool...

Страница 15: ...HECK VALVE CHEMICAL INTRODUCTION WATER OUT TO POOL OR SPA Fig 6 For systems with pumps of less than 2 HP under 80 gpm no external bypass is required Connections are 2 inch unions Plumb the heat pump p...

Страница 16: ...A Fig 7 For systems with pumps of 2 HP or greater over 80 gpm an external bypass is required Adjust the bypass valve to divert a minimum of 40 gpm through the heat pump pool heater Connections are 2 i...

Страница 17: ...Fig 8 Pool Piping for Heat Pump Pool Heater and Gas Pool Heater 17...

Страница 18: ...y Secondary BRANCH MAIN BRANCH MAIN BRANCH MAIN 15 GPM 2 2 15 GPM 2 2 15 GPM 2 2 30 2 2 30 2 2 1 2 30 2 3 45 2 2 45 2 3 45 2 4 60 2 2 1 2 60 2 3 60 2 4 80 2 3 80 2 4 80 2 5 Sizing based on 10 ft sec f...

Страница 19: ...19 Wiring Diagram 208V 230V 3Ph 60Hz Models...

Страница 20: ...Wiring Diagram 460V 3Ph 60 Hz Models 20...

Страница 21: ...21 Wiring Diagram 380V 3Ph 60 Hz Models...

Страница 22: ...until OFF is displayed Wait until a temperature is displayed before beginning the next step 2 Push the SET key until SPA is displayed then push the UP arrow to 104 F Wait until a tempera ture is displ...

Страница 23: ...23...

Страница 24: ...24 Raypak Inc 2151 Eastman Avenue Oxnard CA 93030 805 278 5300 Fax 805 278 5468 Heat Pump Service 1 800 260 2758 Litho in U S A...

Отзывы: