background image

Page 6 of 20 

See examples below of Outdoor Areas: 

 

 

 

 

 

 

Figure 1: 

Overall and framing dimensions. 

 

Содержание MAJESTIC ODGSR36ANAU

Страница 1: ...e instructions thoroughly 2 This appliance must be installed in accordance with a Local Gas Fitting Regulations b Municipal Building Codes c Australian Standard for Gas Appliance Installations AS NZS5601 1 2010 d Any other relevant Statutory Regulation e Manufacturer s installation instructions 3 This appliance must be serviced by a qualified person To suit Models ODGSR36ANAU ODGSR36APAU Gas Types...

Страница 2: ... Chart Hearth Framing and Finishing Final Finishing Gas Specifications Gas Inlet and Burner Pressures High Elevations Valve Access Gas Fitting Line Installation Operating Instructions Log Installation Lava Rock First Firing Flame Adjustment Flame Characteristics Lighting and Operating Instructions Troubleshooting Maintenance Parts List Warranty Service Spare Parts ...

Страница 3: ...tion booklet DO NOT place articles or objects on or against the appliance DO NOT store chemicals or flammable materials near this appliance DO NOT spray aerosols in the vicinity of this appliance whilst it is in operation PRIMARILY A DECORATIVE APPLIANCE NOT CERTIFIED AS A SPACE HEATER TO REDUCE THE RISK OF FIRE OR INJURY FROM BURNS AND FOR THE PROTECTION OF YOUNG CHILDREN OR THE INFIRM A SECONDAR...

Страница 4: ... inspect this appliance annually f Make it a practice to have your gas appliances serviced annually g Control compartments burners and air passages in this appliance should be kept clear of dust and lint Make sure that the gas valve and pilot light are turned off before you attempt to clean this unit h Keep the area around your appliance clear of combustible materials gasoline and other flammable ...

Страница 5: ...combustion are rapidly dispersed by wind and natural convection Any enclosure in which the appliance is used shall comply with one of the following An enclosure with walls on all sides but at least one permanent opening at ground level and no overhead cover and protected from rain Within a partial enclosure that includes an overhead cover and no more than two walls Within a partial enclosure that ...

Страница 6: ...Page 6 of 20 See examples below of Outdoor Areas Figure 1 Overall and framing dimensions ...

Страница 7: ...ntels The height that a combustible mantel is fitted above the fireplace is dependent on the depth of the mantel This also applies to the distance between the mantel leg if fitted and the fireplace For the correct mounting height and widths refer to Figures 2a and 2b Non combustible mantels and legs may be installed at any height and width around the appliance Warning When using paint or lacquer t...

Страница 8: ...nable surface A raised wooden platform A concrete block or other solid object placed beneath each of the four corners of the appliance To mount the appliance Choose unit location Four 4 nailing flanges are supplied with the fireplace located on the fireplace hearth To level the box and secure it firmly in place remove the nailing flanges from the hearth and install at the sides of the fireplace as...

Страница 9: ...Specification always refer to appliance Data plate GAS SPECIFICATION MODEL GAS TYPE GAS CONTROL Max Input MJ h Min Input MJ h ODGSR36ANAU Nat Millivolt Hi Lo 60 43 ODGSR36APAU Propane Millivolt Hi Lo 60 44 GAS INLET AND MANIFOLD PRESSURE kPa NATURAL PROPANE Min Supply Pressure 1 13 2 75 Max Supply Pressure 3 50 3 50 Burner Test point Pressure 0 80 2 50 The gas control valve has test point connecti...

Страница 10: ...Line Installation The gas valve inlet is BSP internal female thread The inlet piping connection sizing and appliance isolating valve must be installed in accordance with AS5601 1 2010 The gas inlet piping can be brought in through the right side of the appliance A hole is provided to allow for the gas pipe installation and testing of any gas connection Figure 6 Parts identification NOTE Test for l...

Страница 11: ...log support 5 Place the top logs onto the locator notches Ensure the logs are secure Figure 11 First Firing Upon completion of the gas fitting line a small amount of air will be trapped in the gas pipe When first lighting the pilot light it will take a few minutes to purge the trapped air Once purging is complete the pilot and burner will light and will operate as outlined in the instruction manua...

Страница 12: ...odically perform a visual check of the pilot and the burner flames refer Figures 13 14 The burner flame is checked after 5 minutes operation It should be mainly a yellow flame with possibly some blue flame at the base The yellow flame should not be producing soot deposits insufficient air The flame should not be excessively blue and noisy excess air Figure 13 Figure 14 If any of the flames appear ...

Страница 13: ...Page 13 of 20 ...

Страница 14: ... enough for good ground For spark at electrode while depressing Piezo 1 8 gap to pilot hood required All wiring connections Replace Piezo ignitor Thermodisk Air in gas pipe Thermopile requires a min of 325Mv Adjust pilot flame height All wiring connections Replace thermopile Thermocouple needs a min of 14mV Defective valve Turn to pilot meter should read greater than 100Mv Thermodisk Faulty gas va...

Страница 15: ...erformed a qualified and suitably licensed service technician In order to properly clean the burner and pilot assembly turn off the gas to the unit remove all logs exposing the burner and pilot assembly Clean all foreign materials from the top of the burner Check to make sure that burner parts are clean Visually inspect pilot Brush or blow away any dust or lint accumulation If the pilot injector i...

Страница 16: ...Page 16 of 20 Parts List ...

Страница 17: ... RAYPAK PALOMA WARRANTY AND EXCLUSIONS TO IT a The decision of whether to repair or replace a component or full replacement of the convection heater is at Raypak Paloma s sole discretion b Where a failed component is replaced under this warranty the balance of the original warranty period will remain effective The replacement does not carry a new Raypak Paloma warranty c Where the heater is instal...

Страница 18: ...other Rheem Service or a Rheem Accredited Service Agent v Faulty plumbing or faulty power supply vi Failure to maintain the outdoor gas fireplace in accordance with the Customer Operating and Installation Manual vii Transport damage viii Fair wear and tear from adverse conditions ix Cosmetic defects x Where it is found that there is no fault with the appliance and the issue s are related to the in...

Страница 19: ...ts original serial numbers or rating label b Is not installed in Australia c Do not possess a copy of the original invoice 5 HOW TO MAKE A CLAIM UNDER THIS WARRANTY If you wish to make a claim under this warranty you need to a Contact Rheem on 131031 and provide owners details address of outdoor gas fireplace a contact number date of purchase require proof of purchase and serial number from the ra...

Страница 20: ...an be carried out on site These Raypak Paloma models have been certified by the Australian Gas Association under Certificate Number 6781 In keeping with our policy of continuous progress and product improvement we reserve the right to make changes without notice Revision Nr 11 10003550 01 December 2011 Rheem Australia Pty Ltd FOR SERVICE TELEPHONE ABN 21 098 823 511 131 031 Australia www paloma co...

Отзывы: