background image

8

84% EFFICIENCY  (TYPE H)

HD101

13

0.7

13

44

8.8

4

17

1.2

HD151

13

0.7

20

44

8.8

6

25

2.9

13

0.7

HD201

13

3.3

26

44

8.9

8

33

5.2

17

1.3

HD251

13

0.7

33

44

9.2

10

44

9.2

21

2.1

14

0.9

HD301

13

0.7

39

44

9.4

12

25

3.1

17

1.3

13

0.7

HD401

17

1.4

40

44

9.8

15

34

5.6

22

2.5

17

1.4

302B

20

<1.0

25

90

9.8

6

50

3.1

25

<1.0

402B

20

<1.0

34

90

10.0

7

67

5.5

34

1.4

22

<1.0

502B

21

<1.0

40

90

10.4

9

84

9.1

42

2.3

28

1.1

21

<1.0

652B

27

1.1

40

90

10.8

12

55

4.1

36

1.8

27

1.1

752B

32

1.5

40

90

11.3

14

63

5.7

42

2.6

32

1.5

902B

38

2.2

40

90

11.7

17

76

8.3

50

3.8

38

2.2

992B

42

1.3

40

132

13.1

13

83

5.2

55

2.3

42

1.3

1262B

53

2.4

40

132

14.8

16

106

9.6

71

4.3

53

2.4

1532B

64

4.0

40

132

16.5

19

129

15.7

86

7.1

64

4.0

1802B

76

6.0

40

132

18.3

23

101

10.7

76

6.0

2002B

84

7.9

40

132

19.0

25

112

13.8

84

7.9

2072B

87

8.5

40

132

19.0

26

116

14.8

87

8.5

2342B

98

12.1

40

132

21.4

30

131

21.1

98

12.1

20°F 

T

Pressure Drops

40°F 

T

30°F 

T

GPM

P Ft

GPM

P Ft

GPM

P Ft

Hi Delta

Model

10°F 

T

GPM

P Ft

Minimum Flow

GPM

P Ft

T °F

Maximum Flow

GPM

P Ft

T °F

Flow Rates

85% EFFICIENCY  (TYPE 

WH)

HD101

9

20

1.8

3.8

7

26

3.0

6.3

4

45

9.2

18.0

1-1/2”

HD151

13

20

1.8

3.8

10

26

3.1

6.3

6

45

9.2

18.1

1-1/2”

HD201

17

20

1.9

3.9

13

26

3.2

6.4

8

45

9.4

18.2

1-1/2”

HD251

21

20

1.9

3.9

16

26

3.2

6.5

9

45

9.6

18.5

1-1/2”

HD301

26

20

1.9

3.9

20

26

3.2

6.5

11

45

9.8

18.7

1-1/2”

HD401

34

20

2.0

4.0

26

26

3.3

6.6

15

45

10.3

19.1

1-1/2”

302B

13

40

2.0

5.1

10

52

3.3

8.3

6

90

9.8

23.7

2”

402B

17

40

2.0

5.1

13

52

3.4

8.4

8

90

10.0

23.8

2”

502B

21

40

2.1

5.2

16

52

3.5

8.6

9

90

10.4

24.2

2”

652B

28

40

2.2

5.3

20

55

4.1

9.7

12

90

10.8

24.7

2”

752B

30

42

2.6

6.0

20

63

5.7

12.8

14

90

11.3

25.1

2”

902B

30

51

3.9

8.7

20

76

8.4

18.6

17

90

11.7

25.5

2”

992B

28

60

2.7

5.2

20

83

5.2

9.7

13

132

13.1

23.6

2-1/2”

1262B

30

72

4.4

7.9

20

106

9.6

16.6

16

132

14.8

25.3

2-1/2”

1532B

30

86

7.1

11.9

20

132

16.5

27.0

20

132

16.5

27.0

2-1/2”

1802B

30

101

10.7

17.1

23

132

18.3

28.7

23

132

18.3

28.7

2-1/2”

2002B

30

112

13.9

21.6

26

132

19.0

29.5

26

132

19.0

29.5

2-1/2”

2072B

30

116

14.8

23.1

27

132

19.0

29.5

27

132

19.0

29.5

2-1/2”

2342B

30

132

21.4

31.8

30

132

21.4

31.8

30

132

21.4

31.8

2-1/2”

87% EFFICIENCY  (TYPE H)

302BE

20

<1.0

26

90

9.8

6

52

3.3

26

<1.0

402BE

20

<1.0

35

90

10.0

8

69

6.0

35

1.5

23

<1.0

502BE

22

<1.0

40

90

10.4

10

87

9.7

44

2.5

29

1.1

22

<1.0

652BE

28

1.1

40

90

10.8

13

57

4.4

38

2.0

28

1.1

752BE

33

1.6

40

90

11.3

15

65

6.1

44

2.8

33

1.6

902BE

39

2.3

40

90

11.7

17

78

8.9

52

4.1

39

2.3

992BE

43

1.4

40

132

13.1

13

86

5.6

57

2.5

43

1.4

1262BE

55

2.6

40

132

14.8

17

110

10.3

73

4.6

55

2.6

1532BE

67

4.3

40

132

16.5

20

132

16.5

89

7.6

67

4.3

1802BE

78

6.5

40

132

18.3

24

104

11.5

78

6.5

2002BE

87

8.5

40

132

19.0

26

116

14.8

87

8.5

2072BE

90

9.1

40

132

19.0

27

120

15.8

90

9.1

2342BE

102

12.9

40

136

22.6

30

136

22.6

102

12.9

Less than Minimum Flow

Exceeds Maximum Flow

Exceeds Maximum Flow

MTS

Hi Delta

Model

Soft

T °F

GPM

P Ft

SHL*

Water Hardness

20°F 

T

Pressure Drops

40°F 

T

30°F 

T

GPM

P Ft

GPM

P Ft

GPM

P Ft

Hi Delta

Model

10°F 

T

GPM

P Ft

Minimum Flow

GPM

P Ft

T °F

Maximum Flow

GPM

P Ft

T °F

Flow Rates

Less than Minimum Flow

NOTES: 98% efficiency available with condensing heat exchanger. (See Specialty Models on pg. 4.)  Minimum flow rates in closed systems may be reduced to a flow rate consistent with a 40°F 

T.

Maximum flow rates are limited by maximum acceptable velocity through the heat exchanger tubes and may be increased by 10% for closed heating systems. Pressure drop would increase 21%.
*SHL = Calculated at 100 feet effective pipe length.

Less than Minimum Flow

Exceeds 

Maximum Flow

Medium

T °F

GPM

P Ft

SHL*

Hard

T °F

GPM

P Ft

SHL*

85% AFUE

Содержание HI DELTA HD101 THRU 2342B

Страница 1: ...Models HD101 thru 2342B Models HD101 thru 2342B...

Страница 2: ...print Raypak s focus on customer satisfaction goes beyond product design Like all Raypak boilers every Hi Delta is factory fire tested assuring reliable start up upon installation For over 60 years Ra...

Страница 3: ...opper finned tubes and optional cupro nickel tubes stand up to even the harshest water conditions 10 Burners Special stainless steel alloy pre mix burners pro vide clean robust combustion and meet all...

Страница 4: ...are feet plus clearances All components except pumps and PRV s are contained inside the cabinet so there won t be any gas valves or fans hanging off the unit The units remain fully serviceable even wh...

Страница 5: ...amount of water from the main system loop into the boiler to maintain the optimum inlet temperature This approach allows the full capacity of the boiler to be utilized to meet the system load while a...

Страница 6: ...3091 1545 1030 773 618 515 442 386 343 309 281 258 238 221 206 402B 399 4111 2055 1370 1028 822 685 587 514 457 411 374 343 316 294 274 502B 500 5152 2576 1717 1288 1030 859 736 644 572 515 468 429 39...

Страница 7: ...502B 500 420 435 425 50 25 1 1 4 2 6 6 22 545 6 652B 650 546 566 553 60 1 2 30 1 4 1 1 4 2 8 6 27 1 4 590 6 752B 750 630 653 638 67 1 2 33 3 4 1 1 4 2 8 6 30 3 4 675 6 902B 900 756 783 765 78 39 1 1...

Страница 8: ...NUAL SHUT OFF DIAGNOSTIC LIGHTS MANUAL SHUT OFF DIAGNOSTIC LIGHTS OPTIONAL PUMP OPTIONAL PUMP 28 1 2 28 1 2 3 1 4 2 1 2 2 1 2 2 1 2 1 3 4 17 3 4 17 3 4 A B K FLUE CONNECTION DIA A B W 3 1 4 32 7 8 32...

Страница 9: ...2 992B 28 60 2 7 5 2 20 83 5 2 9 7 13 132 13 1 23 6 2 1 2 1262B 30 72 4 4 7 9 20 106 9 6 16 6 16 132 14 8 25 3 2 1 2 1532B 30 86 7 1 11 9 20 132 16 5 27 0 20 132 16 5 27 0 2 1 2 1802B 30 101 10 7 17...

Страница 10: ...ch Low Gas Pressure Switch Blocked Vent and Air Pressure Switches High Limit Switch Manual Reset Fixed N A N A N A N A Manual Reset Adjustable Automatic Reset Adjustable 1 Low Water Cut Off 24V With m...

Отзывы: