background image

PUMP - HO

W

A

TER SUPPL

Y

HD101

1/8

1.1

1/8

1.3

1/4

5.7

HD151

1/8

1.1

1/8

1.3

1/4

5.7

HD201

1/8

1.1

1/8

1.3

1/4

5.7

HD251

1/8

1.1

1/8

1.3

1/4

5.7

HD301

1/8

1.1

1/8

1.3

1/4

5.7

HD401

1/8

1.1

1/8

1.3

1/4

5.7

302B

1/8

1.3

1/4

5.7

1/2

7

402B

1/8

1.3

1/4

5.7

1/2

7

502B

1/8

1.3

1/4

5.7

1/2

7

652B

1/8

1.3

1/4

5.7

1/2

7

752B

1/8

1.3

1/2

7

3/4

11

902B

1/4

5.7

1/2

7

3/4

11

992B

1/4

6

1/2

7

3/4

11

1262B

1/4

6

3/4

11

1

14

1532B

1/2

7

1

14

1

14

1802B

3/4

11

1

14

1-1/2

15

2002B

3/4

11

1-1/2

15

1-1/2

15

2072B

3/4

11

1-1/2

15

1-1/2

15

2342B

1

14

1-1/2

15

1-1/2

15

Note: Current draw (Amps) is for pump only.

Soft

Water Hardness

Hard

Medium

HP

Amps

HP

Amps

HP

Amps

Hi Delta

Model

CLEARANCES

Floor*

0”

0”

0”

0”

Rear

1”

24”

12”

24”

Water side

12”

24”

36”

36”

Other side

1”

24”

36”

36”

Top

1”

1”

Unobstructed Unobstructed

Front

Open

24”

Open

24”

Vent

2”

2”

N/A

N/A

Indoor

Minimum

Boiler

Side

Service

Outdoor

Minimum

Service

* Do not install on carpeting.

6

BOILER

HD101

100

85

N/A

85

18-9/16

9-1/4

3/4

1-1/2

4

4

N/A

150

4.7

HD151

150

128

N/A

128

21-7/8

10-7/8

3/4

1-1/2

4

4

N/A

175

4.7

HD201

199

169

N/A

169

25-1/16 12-1/2

3/4

1-1/2

5

4

N/A

200

4.7

HD251

250

213

N/A

213

28-5/16 14-1/8

3/4

1-1/2

5

4

N/A

225

4.7

HD301

299

254

N/A

254

31-9/16 15-3/4

3/4

1-1/2

5

4

N/A

250

4.7

HD401

399

335

N/A

339

38-1/16

19

3/4

1-1/2

6

4

N/A

300

4.7

302B

300

252

261

255

36

18

3/4

2

5

6

18

380

6

402B

399

335

347

339

43

21-1/2

3/4

2

6

6

18-1/2

445

6

502B

500

420

435

425

50

25

1-1/4

2

6

6

22

545

6

652B

650

546

566

553

60-1/2

30-1/4

1-1/4

2

8

6

27-1/4

590

6

752B

750

630

653

638

67-1/2

33-3/4

1-1/4

2

8

6

30-3/4

675

6

902B

900

756

783

765

78

39

1-1/4

2

8

6

36

740

7

992B

990

832

861

842

57-1/8 28-9/16

2

2-1/2

10

10 16-13/16

900

<12

1262B

1260

1058

1096

1071

68-1/2

34-1/4

2

2-1/2

12

10

20-9/16

1010

<12

1532B

1530

1285

1331

1301

79-7/8 39-15/16

2

2-1/2

12

10

24-3/8

1225

<12

1802B

1800

1512

1566

1530

91-1/8 45-9/16

2

2-1/2

14

10

28-1/8

1350

<12

2002B

ª

1999

1679

1739

1699

102-1/2 51-1/4

2

2-1/2

14

10 31-15/16

1450

<12

2072B

2070

1739

1801

1760

102-1/2 51-1/4

2

2-1/2

14

10 31-15/16

1450

<12

2342B

2340

1966

2036

1989

113-7/8 56-15/16

2

2-1/2

16

10 35-11/16

1520

<12

Ref.

Dwg.

pg. 5

Amps

(Cat. I)

Operating

Weight

(lbs.)

T

Ø

W

H

NPT

K

Flue Ø

G

NPT

A

Width

B

MBTUH Output*

87%

(Cat. II)

Type WH

85%

Dimensions (in.)

* Ratings for models HD101-HD401 for natural or propane gas and for elevations up to 2,000 ft. above sea level . For higher elevations, consult the factory.

*

Ratings for models 302B-2342B for natural or propane gas and for elevations up to 4,500 ft. above sea level . For higher elevations, consult the factory.

† Add “E” Suffix to model number.
‡ Current draw is for heater only. (Supply breaker must have a delayed trip.)

ª

Natural gas only. Not available for propane.

Hi Delta

Model

MBTUH

Input*

Type H

1

3

2

85% AFUE

84%

California Bill AB-1953

Raypak is the first manufacturer to comply with California bill
AB-1953. This is new legislation, mandating the maximum lead
content of brass to be less than .25% of the wetted surfaces. This
legislation goes into effect January 1, 2010.

Содержание HI DELTA HD101 THRU 2342B

Страница 1: ...Models HD101 thru 2342B Models HD101 thru 2342B...

Страница 2: ...print Raypak s focus on customer satisfaction goes beyond product design Like all Raypak boilers every Hi Delta is factory fire tested assuring reliable start up upon installation For over 60 years Ra...

Страница 3: ...opper finned tubes and optional cupro nickel tubes stand up to even the harshest water conditions 10 Burners Special stainless steel alloy pre mix burners pro vide clean robust combustion and meet all...

Страница 4: ...are feet plus clearances All components except pumps and PRV s are contained inside the cabinet so there won t be any gas valves or fans hanging off the unit The units remain fully serviceable even wh...

Страница 5: ...amount of water from the main system loop into the boiler to maintain the optimum inlet temperature This approach allows the full capacity of the boiler to be utilized to meet the system load while a...

Страница 6: ...3091 1545 1030 773 618 515 442 386 343 309 281 258 238 221 206 402B 399 4111 2055 1370 1028 822 685 587 514 457 411 374 343 316 294 274 502B 500 5152 2576 1717 1288 1030 859 736 644 572 515 468 429 39...

Страница 7: ...502B 500 420 435 425 50 25 1 1 4 2 6 6 22 545 6 652B 650 546 566 553 60 1 2 30 1 4 1 1 4 2 8 6 27 1 4 590 6 752B 750 630 653 638 67 1 2 33 3 4 1 1 4 2 8 6 30 3 4 675 6 902B 900 756 783 765 78 39 1 1...

Страница 8: ...NUAL SHUT OFF DIAGNOSTIC LIGHTS MANUAL SHUT OFF DIAGNOSTIC LIGHTS OPTIONAL PUMP OPTIONAL PUMP 28 1 2 28 1 2 3 1 4 2 1 2 2 1 2 2 1 2 1 3 4 17 3 4 17 3 4 A B K FLUE CONNECTION DIA A B W 3 1 4 32 7 8 32...

Страница 9: ...2 992B 28 60 2 7 5 2 20 83 5 2 9 7 13 132 13 1 23 6 2 1 2 1262B 30 72 4 4 7 9 20 106 9 6 16 6 16 132 14 8 25 3 2 1 2 1532B 30 86 7 1 11 9 20 132 16 5 27 0 20 132 16 5 27 0 2 1 2 1802B 30 101 10 7 17...

Страница 10: ...ch Low Gas Pressure Switch Blocked Vent and Air Pressure Switches High Limit Switch Manual Reset Fixed N A N A N A N A Manual Reset Adjustable Automatic Reset Adjustable 1 Low Water Cut Off 24V With m...

Отзывы: