![Raypak B0507 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/raypak/b0507/b0507_owners-manual-and-installation-instructions_4058250017.webp)
CONNECTIONS
– PLUMBING
17
WATER FLOW RATE AND PRESSURE DROP
10°C Rise
15°C Rise
20°C Rise
Model
l/sec
kPa
l/sec
kPa
l/sec
kPa
507
2.75
18
1.83
9
1.37
5
538
2.87
6
1.91
3
1.43
3
658
3.58
10
2.39
4
1.79
3
768
4.06
14
2.71
6
2.03
4
868
4.66
22
3.11
8
2.33
5
972
5.26
27
3.5
12
2.63
7
992
5.38
29
3.58
12
2.69
7
1142
6.09
43
4.06
18
3.05
10
1182
6.31
44
4.22
18
3.17
11
1242
6.31
46
4.38
24
3.28
13
1292
6.31
47
4.54
24
3.4
15
1362
6.31
49
4.78
30
3.58
16
1412
6.31
49
5.02
30
3.76
18
1662
6.31
55
5.68
50
4.42
27
1722
6.31
55
5.68
50
5.54
30
1852
6.31
58
5.68
58
4.9
31
1922
6.31
58
5.68
58
5.14
39
2004
10.63
45
7.09
18
5.32
12
2214
12.06
48
8.04
20
6.03
12
2404
12.62
49
8.44
27
6.33
17
2634
12.62
49
9.56
29
7.17
18
2804
12.62
53
9.95
35
7.47
21
3164
12.62
50
11.47
38
8.6
23
3304
12.62
57
11.79
53
8.84
30
3694
12.62
54
12.62
54
10.03
30
3804
12.62
60
12.62
57
10.09
42
4224
12.62
57
12.62
57
11.47
42
Intermittent Pump Operation
Where pump operation is intermittent, a remote thermostat must be fitted in the system and a pump run on timer is
required to remove residual heat from the water heater and prevent nuisance tripping of the high limit thermostat. A
run on timer is available as an optional kit (Rheem part No
56076874).
Minimum Pump Inlet Pressure
Circulating pumps require a minimum inlet pressure in order to operate without cavitation. For the minimum
pressure requirements for Grundfos UPS series pumps, refer to the
“Minimum Pressure Requirements for
Grundfos Series Pumps”
table on page
18
. Minimum pressure requirements for TP series pumps depend on
system characteristics and need to be calculated. Contact your pump supplier for more information.
Содержание B0507
Страница 26: ...CONNECTIONS ELECTRICAL 26 Wiring Diagram for Typical BMS System Interface ...
Страница 28: ...CONNECTIONS ELECTRICAL 28 WIRING DIAGRAMS ON OFF MODELS 1000MJ NG ...
Страница 29: ...CONNECTIONS ELECTRICAL 29 ON OFF MODELS 1000MJ LPG ...
Страница 30: ...CONNECTIONS ELECTRICAL 30 ON OFF MODELS 1000MJ ...
Страница 31: ...CONNECTIONS ELECTRICAL 31 MODULATING MODELS 1000MJ NG DRAWING No 96159611B ...
Страница 32: ...CONNECTIONS ELECTRICAL 32 MODULATING MODELS 1000MJ LPG DRAWING No 96159610C ...
Страница 33: ...CONNECTIONS ELECTRICAL 33 MODULATING MODELS 1000MJ DRAWING No 96159613B ...
Страница 55: ...55 This page is intentionally blank ...