background image

48

CALL OUT

DESCRIPTION

206A

266/266A

336A

399/406A

B

BURNER TRAY 

1-B

Burner Tray w/Burners (sea level)*

010391F

010392F

010393F

010394F

Burner Tray w/o Burners (sea level)*

010395F

010396F

010397F

010398F

Burner Tray w/Gas Valve Nat Millivolt

010399F

010400F

010401F

010402F

Burner Tray w/Gas Valve Pro Millivolt

010403F

010404F

010405F

010406F

Burner Tray w/Gas Valve Nat IID

010407F

010408F

010409F

010410F

Burner Tray w/Gas Valve Pro IID

010411F

010412F

010413F

010414F

    2-B

Burner Spacer/Hold Down Kit

010415F

010416F

010417F

010418F

    3-B

Burner

301210/13

301210/18

301210/22

301210/27

    4-B

Burner Orifice

     Natural Gas

          Burner Orifice #50*

350079F/13

350079F/18

350079F/22

350079F/27

          Burner Orifice #51*

350080F/13

350080F/18

350080F/22

350080F/27

          Burner Orifice #52*

350081F/13

350081F/18

350081F/22

350081F/27

          Burner Orifice #53*

350347F/13

350347F/18

350347F/22

350347F/27

     Propane Gas

          Burner Orifice #57*

350083F/13

350083F/18

350083F/22

350083F/27

          Burner Orifice #58*

350087F/13

350087F/18

350087F/22

350087F/27

          Burner Orifice #59*

350350F/13

350350F/18

350350F/22

350350F/27

          Burner Orifice #60*

350351F/13

350351F/18

350351F/22

350351F/27

          Burner Orifice #61*

350352F/13

350352F/18

350352F/22

350352F/27

5-B

Burner Tray w/o Manifold w/o burners 

010421F

010422F

010423F

010424F

C

CONTROLS

1-C

Thermostat Auto Reset 135 Deg Surface Mount

006725F

006725F

006725F

006725F

2-C

AGS 135° (Auto Gas Shut-Off) - Red Epoxy - prior to 12/2019

600892B

600892B

600892B

600892B

3-C

High Limit 140° - Black Epoxy - prior to 12/2019

600893B

600893B

600893B

600893B

4-C

P.C. Board/Control 

013464F

013464F

013464F

013464F

    7-C

LCD Display

    Units manufactured from 5/2011

013640F

013640F

013640F

013640F

    8-C

Fuse 5 AMP

013733F

013733F

013733F

013733F

5-C

Thermostat Control MV Units Mechanical

003346F

003346F

003346F

003346F

6-C

Temperature Sensor IID Units

009577F

009577F

009577F

009577F

9-C

Thermostat Manual Reset 160 Deg Surface Mount (ASME Only)

016213F

016213F

016213F

016213F

G

GAS VALVE

1-G

Combination Valve - Nat. MV

003898F

003898F

003898F

003898F

Combination Valve - Pro. MV

003899F

003899F

003899F

003899F

Combination Valve - Nat. IID

003900F

003900F

003900F

003900F

Combination Valve - Pro. IID

004306F

004306F

004306F

004306F

HP

HEAT EXCHANGER - POLYMER

1-HP

Heat Exchanger Assy Copper ***

    Units manufactured from 10/2019

017994F

017995F

017996F

017997F

    Units manufactured prior to 10/2019

010043F

010044F

010045F

010046F

Heat Exchanger Assy Cupronickel ***

    Units manufactured from 10/2019

017998F

017999F

018000F

018001F

    Units manufactured from 7/2013 thru 9/2019

014926F

014927F

014928F

014929F

    Units manufactured prior to 7/2013

010356F

010357F

010358F

010359F

    2-HP

Inlet/Outlet Header Complete

    Units manufactured from 10/2019

017959F

017959F

017959F

017959F

    Units manufactured prior to 10/2019

006827F

006827F

006827F

006827F

Inlet/Outlet Header (Includes 6-HP)

    Units manufactured from 10/2019

017965F

017965F

017965F

017965F

    Units manufactured prior to 10/2019

014648F

014648F

014648F

014648F

    3-HP

Return Header (Includes 6-HP)

015095F

015095F

015095F

015095F

    4-HP

Tube Bundle Copper ** & ***

010059F

010060F

010061F

010062F

Tube Bundle Cupronickel ** & ***

    Units manufactured from 7/2013

014930F

014931F

014932F

014933F

    Units manufactured prior to 7/2013

010364F

010365F

010366F

010367F

        5-HP

Baffle (Copper Heat Exchanger)

010038F

005261F

010040F

010041F

Baffle (Cupronickel Heat Exchanger)

    Units manufactured from 6/2013

014934F

014935F

014936F

014937F

    Units manufactured prior to 6/2013

010038F

005261F

010040F

010041F

        6-HP

Flange Nut Kit

008259F

008259F

008259F

008259F

        7-HP

O Ring Gasket (2)

006713F

006713F

006713F

006713F

    8-HP

Sensor Adapter Digital Electronic

006714F

006714F

006714F

006714F

Sensor Well Millivolt

006805F

006805F

006805F

006805F

    9-HP

Bypass Kit

006715F

006715F

006715F

006715F

        10-HP

Bypass Valve

006716F

006716F

006716F

006716F

        11-HP

Bypass Dam / Shaft

006717F

006717F

006717F

006717F

        12-HP

Bypass Spring (All Sizes Included)

006718F

006718F

006718F

006718F

    13-HP

Unitherm Governor 

006719F

006719F

006719F

006719F

    14-HP

Unitherm Governor Plug

006720F

006720F

006720F

006720F

    15-HP

Drain Plug

006721F

006721F

006721F

006721F

    16-HP

Inlet/Outlet Header Dam

N/A  Use 19-HP

N/A  Use 19-HP

N/A  Use 19-HP

N/A  Use 19-HP

17-HP

2" CPVC Connector & Nut (2)

006723F

006723F

006723F

006723F

    18-HP

O Ring (2)

006724F

006724F

006724F

006724F

19-HP

Inlet/Outlet Header Baffle w/Header Dam

006826F

006826F

006826F

006826F

20-HP

ProTek Shield

TM

 Assembly

017960F

017960F

017960F

017960F

**WARNING: The Hydraulic conditions or water chemistry that caused the tube bundle to fail have very likely also damaged the bypass valve and 

Unitherm Governor.  We recommend you replace the Unitherm Governor and inspect the bypass assembly.  Failure to do so could cause premature 

failure of this replacement part.

***WARNING: Copper and Cupronickel heat exchangers and tube bundles are  not interchangeable. Units with suffix "C" must use copper replacement 

parts and units with suffix "X" must use Cupronickel replacement parts.

*FOR INSTALLATION AT OVER 2,000 FEET ABOVE SEA LEVEL, DERATE 4% PER I,000 FEET ABOVE SEA LEVEL.  Refer to the heater's rating plate.

6000.59AH_Atmospheric.indd   48

12/17/2019   2:13:18 PM

Содержание 266

Страница 1: ...ty damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids or other combustible materials in the vicinity of this or any other appliance To do so may result...

Страница 2: ...FACE Wiring diagrams See page 24 and 25 User interface See pages 26 and 27 Remote operation See page 30 QUICK START GUIDE Revision 35 reflects the following changes Model description amended on page 1...

Страница 3: ...21 5 ELECTRICAL WIRING 22 Millivolt Models M suffix 22 Digital Models E suffix 22 Electrical Power Draw 23 Transformer Wiring 23 6 WIRING DIAGRAM MILLIVOLT 24 7 WIRING DIAGRAM DIGITAL 25 8 CONTROLS 2...

Страница 4: ...injury death or substantial property damage if ignored A ACAUTION Indicates the presence of hazards or unsafe practices which could cause minor personal injury or product or property damage if ignore...

Страница 5: ...0 ppm 2 WATER CHEMISTRY NOTE Corrosive water voids all warranties Chemical imbalance can cause severe damage to your heater and associated equipment Maintain your water chemistry according to Table A...

Страница 6: ...O LOCATED ON RATING PLATE THE MODEL AND SERIAL NO CAN ALSO BE FOUND INSIDE THE BEZEL ABOVE THE DISPLAY Figure 1 Rating Plate Location Be sure that you receive the number of packages indicated on the B...

Страница 7: ...ied shall not attempt to fix the equipment nor attempt repairs according to these instructions A AWARNING Improper installation adjustment alteration service or maintenance may damage the equipment cr...

Страница 8: ...etal with ventilated air space over 0 024 sheet metal with ventilated air space Back 4 102 Right 4 102 Left 4 102 Vent 3 76 Indoor Top 24 610 Outdoor Top Unobstructed h 1 25 mm glass fiber or mineral...

Страница 9: ...side corner wall for proper outdoor venting Pagoda Top Installation 1 Insert tabs into keyhole 4 places See Figure 4 detail A 2 Snap tabs into keyholes so as not to pull out See Figure 4 detail B OUTD...

Страница 10: ...on Bolt Washer Field Supplied Ea Pallet Anchor Bracket Use hole closest to unit 4 total 2 x 6 x 1 8 Pallet Anchor Bracket 4 Total Kit 011636 1 4 x 1 3 4 S S Tapcon Bolt and Washer Field Supplied NOTE...

Страница 11: ...test edition of the National Fuel Gas Code U S ANSI Z223 1 or Canada CAN CSA B149 and any local codes that may have jurisdiction The most common approach is the 2 opening method with combustion air op...

Страница 12: ...A Cabinet Width in mm B Flue Dia in mm C Indoor Drafthood in mm D in mm J in mm Gas Conn in Water Conn in Standard Heater w Stackless Top Indoor Draft hood 206A 199 5 58 4 20 508 6 152 61 5 8 1565 10...

Страница 13: ...8 309 3 4 2 268 122 21 9 5 Residential Cupronickel Heat Exchanger Shipping Weights lbs kg Heater Mode BTUH Input 000 kw A Cabinet Width in mm B Flue Dia in mm C Indoor Drafthood in mm D in mm J in mm...

Страница 14: ...stack shall be at least 5 1 5 m in vertical height above the drafthood outlet The vent cap location shall have a minimum clearance of 4 1 2 m horizontally from and in no case below unless a 4 1 2 m ho...

Страница 15: ...sure A ACAUTION Do not use teflon tape on gas line pipe thread Only sealant tape or a pipe compound rated for use with natural and propane gases is recommended Apply sparingly only on male pipe ends l...

Страница 16: ...Figure 15 Honeywell VR8340 Heater Models 206A 406A GAS PRESSURE ADJUSTMENT Figure 16 Robertshaw 7200 Heater Model 206A GAS PRESSURE ADJUSTMENT Figure 17 Robertshaw 7000 BDER Heater Models 266A 336A GA...

Страница 17: ...4 1 1 2 2 25 95 125 473 336A 1 1 4 1 1 2 2 35 132 125 473 399 406A 1 1 4 1 1 2 2 40 151 125 473 When flow rates exceed maximum GPM an external auxiliary bypass valve is required See external bypass va...

Страница 18: ...ders Residential Models Before attaching the 2 inch unions to the inlet outlet header make sure the O rings are properly seated in the grooves Use Aqualube or equivalent non petroleum based lubricant...

Страница 19: ...Governor a built in automatic bypass valve is provided in the In Out header While the Unitherm Governor responds to the changes in water temperature in the heater the internal bypass valve automatical...

Страница 20: ...bed directly to the discharge side of the filter pump 2 The outlet side of the filter is then plumbed to the inlet of the heater and 3 The outlet of the heater is plumbed to the return line to the poo...

Страница 21: ...ONAL ENGINEER Figure 31 Single Pool Heater Installation THIS DIAGRAM IS A RECOMMENDATION AND IS NOT INTENDED TO REPACE AN ENGINEERED PIPING SYSTEM BY A PROFESSIONAL ENGINEER Figure 32 Multiple Pool He...

Страница 22: ...l 7 Allow for water flow through the heater and check for leaks 8 Re attach access panels to the opposite sides For instructions on reversing the heat exchanger connections on ASME models call your fa...

Страница 23: ...r neutral leg of the power supply There should be no connection to the red wire for 120 VAC operation Attach a wire nut to the red wire SUPPLY SIDE RETURN or NEUTRAL HEATER 4 WIRES GROUND L1 RED BLACK...

Страница 24: ...24 6 WIRING DIAGRAM MILLIVOLT 6000 59AH_Atmospheric indd 24 12 17 2019 2 13 00 PM...

Страница 25: ...25 7 WIRING DIAGRAM DIGITAL 6000 59AH_Atmospheric indd 25 12 17 2019 2 13 01 PM...

Страница 26: ...CREW Figure 41 Knurled Screw Location Control Adjustments Millivolt Models Thewatertemperatureiscontrolledbytheheaterthermostat on the upper front panel of the heater The control center contains an On...

Страница 27: ...emperature make sure the control is in the appropriate mode POOL or SPA and push the UP or DOWN buttons By default the setpoint range is 50 104 F 10 40 C See MAX Settings on page 28 to increase the MA...

Страница 28: ...P and DOWN buttons for 5 7 seconds until FAULTS CLEARED appears This operation resets the Fault History file to 0 and clears all the stored faults Fahrenheit or Celsius Refer to step one above to acce...

Страница 29: ...shut PV Output Fault Pilot gas valve output is not in commanded state MV Output Fault Main gas valve output is not in commanded state LoNox Tab Fault Voltage is sensed at the Lo NOx terminal on a non...

Страница 30: ...the POOL Mode Heating in the SPA Mode Remote Mode Figure 51 Remote Control Menu Remote Operation Millivolt models are not designed for operation with remote control sytem Activating the Remote To act...

Страница 31: ...the heater See Figure 54 For activation of the remote control see section on page 30 3 Wire Remote Control Using Three Position Switch Pool Off Spa or Low Off High This application assumes that both...

Страница 32: ...itch 2 Set the heater control to the OFF mode 3 Turn the filter pump ON and confirm that the pressure switch is closed use a multimeter to check If the pressure switch fails to close either the switch...

Страница 33: ...nel Pilot Safety Millivolt Models Heaters equipped with the standing pilot millivolt system employs a pilot which act as a safety device to shut down the flow of gas to the main burners and the pilot...

Страница 34: ...5 Remove the four 4 screws holding down the flue collector Remove the flue collector 6 If ProTek Shield Assy is attached to the heater disconnect flange nuts on Inlet Outlet header remove ProTek Shie...

Страница 35: ...piratory protection to avoid inhalation of airborne dust and airborne fiber particles Immersion Well Replacement Millivolt 1 Shut off water to heater and drain heat exchanger 2 Remove access panel on...

Страница 36: ...bsection After Start Up Feel the inlet and outlet pipes Outlet pipe should be only slightly warmer than the inlet It should not be hot A AWARNING Should overheating occur or the gas supply fail to shu...

Страница 37: ...osition 4 Remove heater door panel 5 Push in gas control knob slightly and turn clockwise to OFF NOTE Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force 6 Wait 5 mi...

Страница 38: ...ical power to the appliance 4 This appliance is equipped with an ignition device which automatically lights the pilot Do not try to light the pilot by hand 5 Remove heater door panel 6 For Honeywell v...

Страница 39: ...ressure is higher than usual 4 The pump may have lost its prime and be running dry Check the pressure on the filter If there is no pressure then you are not moving water or your gauge is broken Try to...

Страница 40: ...5 F and 110 F 40 C and 43 C U G inoperative Check movement by putting in hot water 110 F 43 C or higher If no movement replace Air starvation Refer to installation instructions Improper venting Follow...

Страница 41: ...500mV check gas pressure Also check for insects or debris in the pilot burner If main burner fires remove jumper Replace gas valve If main burner does not fire remove jumper Remove both TH wires from...

Страница 42: ...gas control Check for 24 VAC across PV MV PV terminals on PC board If voltage is okay replace gas control if not replace PC board NOTE If PC board goes into lockout reset system Lockout is used on L...

Страница 43: ...istance k 261 1 199 0 153 1 118 8 93 0 73 3 58 3 51 0 If okay replace Circuit Board Sensor Failure Inspect thermister wires and connector at Terminal P1 Check resistance value of the thermister Refere...

Страница 44: ...warranties must be properly tagged with a return parts tag completely filled in with the heater serial number model number etc and shipped to the Company freight prepaid If determined defective by th...

Страница 45: ...HP 10 S 3 V 1 V 2 V 14 M I S I3 S 2 S 5 HP 4 HP 7 HP 6 HP I2 S 6 HP 15 HP 3 HP 7 S 3 R 4 S 17 HM 11 S 4 C 9 M 8 S 13 M 12 M 3 S 4 B 2 B 5 M 5 B 1 B 1 G 1 J 4 S 5 S 6 S 14 M 1 R 2 R 2 J 7 HP 3 B 10 M...

Страница 46: ...HP 20 HP 26 HM 27 HM 6 C 8 HP 6 C 8 HP 4 S 2 S 6 HM 3 HM 7 HM 5 HM 20 M 1 M 21 M 19 M OPTIONAL 2 HM FOR UNITS WITH ASME CAST IRON HEADERS PRIOR TO 12 2019 OPTIONAL 16 HM 15 HM 12 HM 9 HM 10 HM 2 C 6...

Страница 47: ...HP 12 HP 13 HP 2 HP 14 HP 8 HP 6 C 19 HP 6 M OPTIONAL HONEYWELL MILLIVOLT PILOT FOR UNITS WITH POLYMER HEADERS PRIOR TO 10 2019 6 M 17 HP 14 HP 13 HP 2 HP 10 HP 12 HP 11 HP 16 HP 1 C 1 M 6 C 19 HP 19...

Страница 48: ...018000F 018001F Units manufactured from 7 2013 thru 9 2019 014926F 014927F 014928F 014929F Units manufactured prior to 7 2013 010356F 010357F 010358F 010359F 2 HP Inlet Outlet Header Complete Units m...

Страница 49: ...018007F 018007F 018007F 28 HM U G Bypass Assembly 017958F 017958F 017962F 017962F CALL OUT DESCRIPTION 206A 266 266A 336A 399 406A J CONTROL BOX 1 J Transformer 120 240 24V 006736F 006736F 006736F 00...

Страница 50: ...9 2012 013867F 013868F 013869F 013870F Green 010382F 010383F 010384F 010385F Jacuzzi N A 016698F N A 016699F 14 S Screw Retainer 006744F 006744F 006744F 006744F 4 S Access Panel Set 3 Pcs Units with...

Страница 51: ...51 NOTES 6000 59AH_Atmospheric indd 51 12 17 2019 2 13 18 PM...

Страница 52: ...6000 59AH_Atmospheric indd 52 12 17 2019 2 13 18 PM...

Отзывы: