Installation

Page 6

Figure 7.  Vent Piping Requirements.

The weight of the vent stack or chimney must not rest on

heater drafthood.  Support must be provided in compliance
with applicable codes.  The heater top and drafthood must be
readily removable for maintenance and inspection.  Vent pipe
should be adequately supported to maintain proper clear-
ances from combustible construction.

Type "B" double-wall or equivalent vent pipe is recom-

mended.  However single-wall metal vent pipe may be used
as specified in the latest edition of the National Flue Gas
Code ANSI Z223.1 (Canada - CAN/CGA-B149.1 and
B149.2).

G

AS

C

ONNECTIONS

Gas piping must have a sediment trap ahead of the

heater gas controls, and a manual shut-off valve located out-
side the heater jacket.  All gas piping should be tested after
installation in accordance with local codes.

Figure 8.  Gas Line Sediment Trap.

(field supplied)

(field supplied)

(field supplied)

Vent Pipe

Drafthood

Heater

5‘ MIN

2‘ MIN

2‘ MIN

Vent Cap

10’ or

Less

CAUTION

THE HEATER AND ITS MANUAL SHUT-OFF VALVE MUST
BE DISCONNECTED FROM THE GAS SUPPLY DURING
ANY PRESSURE TESTING OF THAT SYSTEM AT TEST
PRESSURES IN EXCESS OF 1/2 PSIG (3.5 KPA).  THE
HEATER AND ITS GAS CONNECTIONS SHALL BE LEAK
TESTED BEFORE PLACING THE APPLIANCE IN OPERA-
TION.  USE SOAPY WATER FOR LEAK TEST.  DO NOT
USE OPEN FLAME.

NOTE:  Do not use Teflon tape on gas line pipe
thread.  A flexible pipe sealant suitable for LP gases
is  recommended.

G

AS

P

RESSURE

R

EGULATOR

If adjustment is needed, remove seal and turn adjustment

screw clockwise to increase pressure or counterclockwise to
decrease pressure.

Table 4.  Gas Pressure.

*Static means without heater operating.  Dynamic refers to heater operating.

G

AS

P

RESSURE

A

DJUSTMENT

L

OCATIONS

Figure 9A.  Honeywell DSI VR 8205 Gas Valve.

Figure 9B.  

Robertshaw MV Gas Valve.

Gas Pressure Adjustment

B.

Gas Pressure Adjustment

A.

Gas Pressure*

Natural Gas

Propane Gas 

Max Inlet (static)

10.5" W.C.

13" W.C.

Min Inlet (dynamic)

7" W.C.

11" W.C.

Manifold Gas (dynamic)

3.5" W.C.

10" W.C.

Содержание 130A

Страница 1: ...IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas s...

Страница 2: ...ined from your pool or spa builder accredited pool shop or chemical supplier for the correct levels for your water AUTOMATIC CHLORINATORS CHEMICAL FEEDERS All chemicals must be introduced and complete...

Страница 3: ...a fire or explosion causing property damage bodily injury or death Should you have any problems understand ing the warnings and instructions in this manual STOP and get help from a qualified installer...

Страница 4: ...rd for Gas Fired Pool Heaters The heater can be used either indoors or outdoors If necessary the top of the heater can be changed after installation to accommodate indoors or out doors WARNING USE OF...

Страница 5: ...a level base such as cementable slab cement blocks or another non combustible surface An alternate method for providing a base for com bustible floors is illustrated Heaters may not be installed on c...

Страница 6: ...UNITS ONLY In areas where high winds are frequent it may be neces sary to locate the heater a minimum of 3 from high vertical walls or install a wind break so the heater is not in direct wind current...

Страница 7: ...B149 2 As much as possible avoid long horizontal runs of vent pipe and too many elbows If installation requires hori zontal runs the vent pipe must have a minimum of 1 4 in per ft rise and should be...

Страница 8: ...plied field supplied Vent Pipe Drafthood Heater 5 MIN 2 MIN 2 MIN Vent Cap 10 or Less CAUTION THE HEATER AND ITS MANUAL SHUT OFF VALVE MUST BE DISCONNECTED FROM THE GAS SUPPLY DURING ANY PRESSURE TEST...

Страница 9: ...d 3 The outlet of the heater is plumbed to the return line to the pool or spa The pump filter and heater are thus plumbed in series Plumbing from the heater back to the pool or spa must not have any v...

Страница 10: ...e valve as an auxiliary bypass valve AUXILIARY BYPASS VALVE ADJUSTMENT To set bypass With clean filter adjustment is made by feeling the inlet and outlet pipes at the heater Outlet pipes should be sli...

Страница 11: ...ransformer for 120 VAC input power hookup Heater must be electrically grounded and bonded in accordance with local codes or in the absence of local codes with the latest edition of the National Electr...

Страница 12: ...mit HI Limit In Out In Out Thermostat Manual Switch Switch Switch AGS Water Press Gas Valve Roll Out Valve Pilot Generator To Firemans Switch field installed Optional BK BK R Y BK TH PP W R PP TH V BK...

Страница 13: ...y gas control which has been under water 1 STOP Read the safety information above 2 Set the thermostat to the lowest setting 3 Turn off all electrical power to the appliance 4 This appliance is equipp...

Страница 14: ...to Off unless knob is pushed in slightly Do not force 6 Wait 5 minutes to clear out any gas If you then smell gas STOP Follow B in the safety information above If you don t smell gas go to the next st...

Страница 15: ...FOR FREEZE PROTECTION WHEN HEATER IS USED DURING FREEZ ING WEATHER CARE MUST BE TAKEN TO AVOID FREEZE UPS CONTINUOUS PUMP OPERATION IS A MUST ADDITIONAL PROTECTION MAY BE REQUIRED THE HEATER IS NOT WA...

Страница 16: ...RATE MEETS THE REQUIREMENTS LISTED IN TABLE 6 WATER PRESSURE SWITCH ADJUSTMENT Figure 24 Water Pressure Switch Adjustment 1 With pump and heater on turn adjustment knob clock wise until a click is hea...

Страница 17: ...am of heater 3 Remove front door 4 Disconnect gas line from gas valve 5 Remove 2 screws that mount burner tray to unit and 2 screws that secure gas valve to jacket 6 Disconnect wires that terminate at...

Страница 18: ...move 2 screws that mount the igniter to the burner tray 3 Remove igniter from burner tray 4 Reverse above procedure to reinstall Figure 29 Direct Spark Igniter Spark Gap 0 15 0 18 PILOT REMOVAL AND CL...

Страница 19: ...from the heater and wash with a garden hose making sure soot is removed from spaces between fins 5 Reverse above procedure to reinstall NOTE In extreme cases it may be necessary to do high pressure cl...

Страница 20: ...gure 14 Air starvation Refer to installation instructions Improper venting Follow recommended installation instructions Insects or debris clogging burner intake ports Clean burners Pilot outage Low ga...

Страница 21: ...across each high limit and remove jumper Replace thermostat Replace high limit that prevented from firing Jump across both TH wires on gas valves Check gas supply gas line size gas pressure Also chec...

Страница 22: ...White Negative Red Positive 2 Pilot Load 500mV 100 Pilot generator connected to valve Power applied to pilot solenoid TP Thermopile Robertshaw PP Power Pile Honeywell TH TP Common Invensys TH PP Comm...

Страница 23: ...o run at its normal flow rate Turn knob to a desired temperature zone Yes Yes Yes No No No Turn switch ON After 6 seconds does the igniter spark Does the burner tray light Does the burner tray stay li...

Страница 24: ......

Отзывы: