RAYN Installation Guide

Lamp Head and LED Driver

Install the LED Driver

WARNING:

Risk of electric shock! This device utilizes high

voltage and should only be installed by a qualified installer or
electrician. Follow all local codes for installation. Before
terminating the AC power wiring verify that the main breaker is in
the off position and follow the proper lockout/tag out procedures
per NFPA Standard 70E or applicable local regulations.

AVERTISSEMENT :

Risque de décharge électrique! Cette

appareil utilise une haute tension et ne doit être installé que par
un installateur qualifié ou un électricien. Suivez tous les codes
locaux pour l'installation. Avant de raccorder le câblage du
courant alternatif, vérifiez que le disjoncteur principal est en
position d'arrêt et suivez les procédures de
Consignation/Déconsignation prescrites par la norme NFPA 70E
ou aux réglementations locales applicables.

CAUTION:

Risk of personal injury and/or product damage. Handle

the LED driver carefully. Do not lift, suspend, or move the driver
using the input or output wires.

1. Using M4 (#8) hardware, secure the LED driver to a suitable structure using the

built-in mounting flange. The installation location must be within 3 m (10 ft) of the
desired Lyda lamp head installation location.

2. Connect the lamp cable from the LED driver to the installed Lyda lamp head. The

connection is secured by rotating the locking ring counterclockwise until finger
tight.

3. If dimming control is required, connect the optional controller. See the

Lyda

System Installation and User Manual

for details.

4. Connect the LED driver to the power source. If using a connectorized power input

cable, simply plug the unit into the distributed power input receptacle. If using a
bare end power input cable, terminate the wiring according to the cable type and
local codes.

Model

Type

Color

Power Cable,
US Color Code

ground/earth

green

line

black

neutral

white

Power Cable, IEC
Color Code

protective
earth

green/yellow

line

brown

neutral

blue

Reference

See

rayngrowingsystems.com/products/lyda-system/

for the complete

Lyda Lamp

Head and LED Driver Lamp Head and LED Driver Installation and User Manual

including power up and operation instructions.

Lamp Head and LED Driver

Page 7 of 8

RAYN

Содержание Lyda

Страница 1: ...top for straight down installation and two others for sideways installation The lamp head must be supported on both ends when installed 3 Lamp Cable Input Attach the lamp cable from the LED Driver to...

Страница 2: ...Ambient Temperature Relative Humidity Protection Lyda lamp head 10 C to 35 C 14 F to 95 F storage maximum is 45 C 113 F 20 100 condensing non corrosive sulfur residue free suitable for damp locations...

Страница 3: ...spositif de d connexion de l alimentation ne soit accessible LED Driver 100 277 VAC 50 60 Hz input The LED driver is a UL Class I apparatus This equipment must be grounded The LED driver is provided w...

Страница 4: ...mage Handle the LED driver carefully Do not lift or move the driver using the input or output wires CAUTION RISK OF SHOCK Do not make or break connection under load ATTENTION RISQUE DE CHOC ELECTRIQUE...

Страница 5: ...ect water flow on the lamp head Do not install any Lyda system component underneath the irrigation system Note For use with the approved power source only The light source in this lamp head is not use...

Страница 6: ...are and installation location must support four times the weight of the Lyda lamp head lamp cable and any installed accessories The lamp head must be installed within 3 m 10 ft of the LED driver 1 Eac...

Страница 7: ...driver using the input or output wires 1 Using M4 8 hardware secure the LED driver to a suitable structure using the built in mounting flange The installation location must be within 3 m 10 ft of the...

Страница 8: ...RAYN Installation Guide Lamp Head and LED Driver Lamp Head and LED Driver Page 8 of 8 RAYN...

Отзывы: