ST60 Graphic Display Commissioning Guide
receive a satisfactory power supply. The requirements for power connections
are detailed in the following table.
:
Connection procedure
To connect your ST60 Graphic Display:
1. Ensure that:
•
Power to the existing SeaTalk system is switched off.
•
The conditions described under
Power requirements
are fulfilled.
2. Plug the SeaTalk cable(s) from the rear of the display into a vacant
SeaTalk connector on an adjacent instrument. You can either break the
existing SeaTalk chain to connect as shown in the following illustration,
or connect to an existing product at the end of the SeaTalk bus.
SeaTalk cable run
No. of instruments
Power connections
Up to 10 m
13 maximum
To one end of the system
26 maximum
To both ends of the system
Up to 20 m
7 maximum
To one end of the system
13 maximum
To both ends of the system
D4311-1
5 A fused,
12 V dc supply
(typically provided
by autopilot)
Red
Screen
Red
Screen
1
2
3
4
Instruments
5 to 16
17
18
19
20
SeaTalk power connections
81228_1.book Page 2 Wednesday, November 19, 2003 10:29 AM