44
ST1000 Plus & ST2000 Plus Tiller Pilots
SeaTalk cabling
CAUTION:
Protect the power supply for the SeaTalk 12 V (red) line with a 5 A
fuse (or equivalent circuit breaker) fitted as close to the tiller pilot
as possible.
If required, the tiller pilot can be wired to the SeaTalk bus using a suitable SeaTalk
interface cable (part numbers: D229 flat moulded plug, D179 male round plug,
D181 female round plug).
Connect the SeaTalk cable to the tiller pilot socket as shown below. As well as
sharing SeaTalk data, the tiller pilot can also be used to supply power to the
SeaTalk instruments.
Raymarine produce a range of SeaTalk accessory cables you can use to connect
the tiller pilot to SeaTalk instruments and control units:
• flat plugs for recent SeaTalk equipment (e.g. ST30, ST40, ST60)
• round plugs for older SeaTalk equipment (e.g. ST50)
D366-2
Supply (0 V)
Supply (+12 V DC)
12 A fuse
Socket
Yellow (SeaTalk data)
Screen (SeaTalk 0 V)
Red (SeaTalk 12 V)
with 5 A fuse
SeaTalk
instruments
SeaTalk
interface cable
81130_5.book Page 44 Wednesday, June 15, 2005 3:48 PM