LED
color
LED code
Status
User action
Amber
3 blinks
Under
voltage
(<10.2V)
• Ensure power cable and connections
are secure and free from damage.
• Ensure power supply cabling is
consistent with recommendations.
• If problem persists contact Raymarine
technical support.
Red 3
blinks
Over
voltage
(>34.2V)
• Ensure power supply levels are
consistent with recommendations.
• If problem persists contact Raymarine
technical support.
Note:
During a software upgrade process the LED will be solid Green and change to blinking
Green on successful completion.
Note:
If any other LED sequence other than described above is seen and persists please contact
Raymarine technical support.
Resetting the sonar
The reset function restores the unit to its factory default values.
Note:
Performing a factory reset will clear speed and temperature calibration settings and the
depth offset.
1. Using a compatible Raymarine multifunction display, open the Sonar app.
2. Open the
Settings
page.
3. Select the
Sounder
tab.
4. Select
Reset sounder
.
5. Select
Yes
to confirm.
The unit will now be reset to factory default settings.
System checks and troubleshooting
85