Commissioning menu
Commissioning menu options are dependant on connected autopilot system.
Menu option
Description
Evolution autopilots
SeaTalk and SPX
SmartPilots
Dockside Wizard
Initiates the Dockside wizard
process.
Yes
Yes
Sea Trial Wizard
Initiates the Sea Trial wizard
process.
N/A
Yes
Motor phasing
Initiates the motor phasing
(drive check) wizard
N/A
Yes
Swing Compass
Initiates the swing compass
wizard
N/A
Yes
Auto Learn
Initiates the Auto Learn
process
N/A
Yes
Align Compass GPS
(1)
Initiates the align compass to
GPS heading wizard
Yes
Yes
Align Compass
(1)
Manual adjustment of the
compass offset
• -10° to 10°
• -179° to 180°
Pilot Factory Reset
Resets the autopilots course
computer to factory default
settings.
• Yes
• No
• Yes
• No
Restart Compass
Restarts the compass
• Yes
• Cancel
N/A
Compass Lock
Locks the compass from
performing further automatic
linearization.
• On
• Off
N/A
Debug Level
(1)
Sets the debug value for
troubleshooting purposes.
The recommended Debug
setting is 7.
Note:
The Debug
level should only be set
temporarily, usually when
requested by Technical
Support as part of a
troubleshooting sea trial.
• 0 — 63
N/A
ACU Debug Level
(1)
Sets the debug value for
troubleshooting purposes.
The recommended Debug
setting is 7.
Note:
The Debug
level should only be set
temporarily, usually when
requested by Technical
Support as part of a
troubleshooting sea trial.
• 0 — 127
N/A
Note:
(1)
Option not available when
Calibration Lock
is turned On.
User Settings
When connected to a SeaTalk autopilot system a
User settings menu will be available.
The User settings menu can be accessed from:
Main Menu > Set up > Autopilot calibration >
User settings
. Once entered the user settings
menu will cycle through all available options. These
options shall be available to users when calibration
lock is turned on.
Set up menu options
89
Содержание P70
Страница 2: ......
Страница 4: ......
Страница 10: ...10 p70 p70R ...
Страница 14: ...14 p70 p70R ...
Страница 28: ...28 p70 p70R ...
Страница 29: ...Chapter 5 Installation Chapter contents 5 1 Mounting on page 30 Installation 29 ...
Страница 38: ...38 p70 p70R ...
Страница 48: ...48 p70 p70R ...
Страница 58: ...58 p70 p70R ...
Страница 68: ...68 p70 p70R ...
Страница 74: ...74 p70 p70R ...
Страница 75: ...Chapter 11 Pilot controller alarms Chapter contents 11 1 Alarms on page 76 Pilot controller alarms 75 ...
Страница 80: ...80 p70 p70R ...
Страница 94: ...94 p70 p70R ...
Страница 110: ...110 p70 p70R ...
Страница 118: ...118 p70 p70R ...
Страница 121: ......