6.3 Data master
Where a system contains more than one unit
capable of displaying a data type, the unit physically
connected to the transducer must be set as the data
master and any other units set as a repeater.
Checking the software version and
instrument status
You can check the instrument display’s software
version and status by following the steps below.
Note:
The i60 CH Wind instrument is a repeater
display. You cannot check or change the
instrument status of an i60 CH Wind display
From the software version page:
During normal operation:
1. Press and hold the
Display
and
True / App
buttons at the same time for approximately 4
seconds , until the Software Version page is
displayed.
2. Press the
Display
button to show the Instrument
Status page.
The instrument status is displayed (
r 0
= master
and
r 1
= repeater).
Note:
The Software Version and Instrument Status
pages are temporary pages and will time-out
automatically after 8 seconds of inactivity.