Alarm Message
Possible causes
Solution
PILOT RESET NORMAL
(UNEXPECTED HARDWARE
RESET)
• Autopilot resets due to an
external event (such as use
of the sleep switch, or faulty
wiring causing the autopilot
components to power cycle).
Check all system wiring,
especially power-related
wiring.
PILOT RESET EXCEPTION
(UNEXPECTED SOFTWARE
RESET)
The EV-1 / EV-2 software has
detected a fault it cannot
recover from, and has reset the
pilot.
Wait approximately 1 minute
for the EV-1 / EV-2 to reset and
re-initialize.