Note:
Connectors 1 and 2 are rotavecta connections,
connectors 3 to 7 are for wind transducers.
Making transducer connections
Although the transducer cable is fitted with spade connectors for
direct connection to the rear of the unit, it may be necessary to
remove these to facilitate installation, e.g. if the cable has to be
routed through narrow apertures. 1/8th spade terminals will be
required (not supplied), to replace those removed. When fitting
the new spade connectors, prepare the cables as detailed below:
3 mm
6 mm
50 mm
1
2
D12359-1
1. Prepare the cable as shown in 1 above.
2. Fold back the wire strands and insert into the new spade
connector as shown in 2 above.
3. Ensure the wire strands do not extend beyond the rear of the
spade connector insulation.
4. Crimp the connector to the wire.
iTC-5 connection
Transducers can be connected to a SeaTalk
ng
network using
Raymarine's Instrument transducer converter (iTC-5) and an i70
instrument, the data can then be repeated on an i50 / i60 unit.
12 V
D12033-3
1
2
3
4
5
6
7
8
1
i50 Depth (Repeater)
2
i70 Instrument (Master)
3
i50 Speed (Repeater)
4
i60 Wind (Repeater)
5
iTC-5
6
Depth transducer
7
Wind vane transducer
8
Speed transducer
Note:
Transducers connected to the iTC-5 must be calibrated
using an i70 (master) unit. Transducers connected to the
iTC-5 cannot be calibrated using an i50 / i60.
Making iTC-5 transducer connections
For instructions on connecting transducers to your iTC-5 refer
to the iTC-5 handbook.
Power connection
Power is supplied to the product over the SeaTalk
ng
network.
A SeaTalk
ng
system requires one 12 V dc supply, connected to
the SeaTalk
ng
backbone. This can be provided:
• By a battery via the distribution panel, or
• From a Raymarine course computer, via a SeaTalk or a
SeaTalk
ng
system.
Power connection example
SeaTalk
ng
power connection
SeaTalk
ng
D12391-1
12 V
3
1
2
1
SeaTalk
ng
instrument.
2
SeaTalk
ng
instrument.
3
12 V dc vessel power supply.
Warning: Grounding not required
This product is fully insulated and does NOT
require separate grounding.
Warning: Positive ground systems
Do not connect this unit to a system which has
positive grounding.
SeaTalk power protection
The power supply must be protected by a 5 A fuse or a circuit
breaker providing equivalent protection.
Raymarine recommends that the power is connected to a
SeaTalk system in such a way that the current drawn on each
side of the power connection point is equal.
SeaTalk power cables
Part number
Description
D229
SeaTalk power cable.
SeaTalk
ng
power protection
The power supply must be protected by a 5 A fuse or a circuit
breaker providing equivalent protection.
Raymarine recommends that the power is connected to a
SeaTalk
ng
system in such a way that the current drawn on each
side of the power connection point is equal.
SeaTalk
ng
power cables
Part number
Description
A06049
SeaTalk
ng
power cable
Cables and connections
21
Содержание E70061
Страница 2: ......
Страница 4: ......
Страница 6: ...6 i60...
Страница 18: ...18 i60...
Страница 24: ...24 i60...
Страница 34: ...34 i60...
Страница 38: ...38 i60...
Страница 39: ...Chapter 8 Using alarms Chapter contents 8 1 Alarms on page 40 Using alarms 39...
Страница 58: ...13 4 Converters Part number Description E22158 SeaTalk to SeaTalkng Converter 58 i60...
Страница 60: ...60 i60...
Страница 61: ......
Страница 62: ...www raymarine com...