background image

14

DSM25 Owner’s Handbook

The dark layers indicate a good echo; the lighter areas weaker echoes. This could 
mean that the upper layer is soft and therefore allowing sound waves to pass to 
the more solid layer below.
It is also possible that the sound waves are making two complete trips – hitting 
the bottom, bouncing off the boat, then reflecting off the bottom again. This can 
happen if the water is shallow, the bottom is hard, or gain is set high.

How Targets are Displayed

When a target is detected, it is displayed on screen as a mark. The shape and size 
of this mark is influenced by a combination of factors:

Boat speed

The shape of the target changes along with your speed. Slower speeds return 
flatter, more horizontal marks. As your boat’s speed increases, the target will tend 
to thicken and arch slightly until at fast speeds the mark resembles a double 
vertical line.

The depth of the target

The closer the target to the surface the larger the mark on screen. 

Note:  

The depth of individual targets can be displayed by switching on the Target Depth 

ID in the Fishfinder Alarms Setup Menu.

The size of the target

The larger the target, the larger the return on the fishfinder display. The size of a 
fish target is however dependent upon the size of the fish’s swim bladder rather 
than its overall size. This swim bladder will vary in size between different breeds of 
fish.

The frequency of the transducer

The same target will appear differently when the transducer frequency is 
changed. The lower the frequency the broader the mark.

81254.book  Page 14  Monday, March 6, 2006  2:29 PM

Содержание DSM25

Страница 1: ...DSM25 Digital Sounder Module Owner s Handbook Document number 81254 2 Date March 2006...

Страница 2: ...and registered trademarks Raymarine is a registered trademark of Raymarine plc All other product names are trademarks or registered trademarks of their respective owners Contents of this handbook Raym...

Страница 3: ...stallation 17 2 2 Unpacking and Inspecting the Components 17 2 3 Optional Equipment 18 2 4 Selecting Sounder Module Mounting Location 18 2 5 Mounting the Sounder Module 19 2 6 Cable Runs 21 2 7 System...

Страница 4: ...OLL PAUSE RESUME 39 3 9 Determining Target Depths and Distance 39 3 10 Using Waypoints 40 Chapter 4 Fishfinder Setup 41 4 1 DSM Setup 43 Depth Digit Size 43 Depth Lines 43 Palette 43 Depth Offset 44 S...

Страница 5: ...Safety Guidelines 50 5 2 Resetting the Sounder 51 Power on Reset 51 Factory Reset 51 5 3 Problem Solving 52 Common Problems and Their Solutions 52 Status LED 53 5 4 How to Contact Raymarine 54 On the...

Страница 6: ...6 DSM25 Owner s Handbook...

Страница 7: ...o the handbook supplied with the A65 display Safety Notices This equipment must be installed and operated in accordance with the instructionscontainedinthismanual Failuretodosocanresultinpersonalinjur...

Страница 8: ...y will perform under all conditions it is important to understand what factors could affect the operation of the product TheguidelinesgivenheredescribetheconditionsforoptimumEMCperformance butitisreco...

Страница 9: ...e run The following illustration shows typical cable suppression ferrites sometimes used with Raymarine equipment To ensure EMC compliance always use these ferrites if supplied by Raymarine for use wi...

Страница 10: ...and updating may change product specifications without prior notice As a result unavoidable differences between the product and handbook may occur from time to time For the latest version of this or...

Страница 11: ...ail and optimal color allocation The DSM25 digital bandwidth adaptation adjusts the receiver band width dynamically from very wide to very narrow as required by the actual water conditions This provid...

Страница 12: ...ture such as reefs and shipwrecks Target images indicating fish The bottom depth You can customize the sounder to Display or hide the depth of the targets Display or hide the depth lines Change the co...

Страница 13: ...which displays a visual interpretation of the underwater view The strength of echoes is indicated on the display by different colors You can use this information to determine the bottom structure the...

Страница 14: ...nges along with your speed Slower speeds return flatter morehorizontalmarks Asyourboat sspeedincreases thetargetwilltend to thicken and arch slightly until at fast speeds the mark resembles a double v...

Страница 15: ...to Use this Handbook This handbook describes how to install and operate a DSM25 with your A65 display unit Chapter 2 provides planning considerations and detailed instructions for installing the DSM2...

Страница 16: ...16 DSM25 Owner s Handbook DSM25 Transducer RS12 GPS A65 Display D7746 1 Power Supply...

Страница 17: ...plan the installation considering Correct transducer for your application Location of the sounder module as described in Section 2 4 2 2 Unpacking and Inspecting the Components Unpack your system care...

Страница 18: ...main console When planning the installation the following should be considered to ensure reliable and trouble free operation Access There must be sufficient space below the unit to enable cable con ne...

Страница 19: ...re it is well ventilated and free from gasoline fumes 2 5 Mounting the Sounder Module The DSM25 can be mounted either above or below deck using the supplied hardware To allow for ease of cable connect...

Страница 20: ...youshouldoverdrillthesurfacetopreventthe gelcoat from chipping whendriving inthescrew Before drilling the pilot hole hand drill the marked locationwith anoversized bit and countersink to approximately...

Страница 21: ...ngercablesarealsoavailable see Optional Equipment on page 18 Transducer cable supplied with the transducer This 30 ft 10 m cable has a connector plug with an outer nut that you must attach at one end...

Страница 22: ...eplaced it cannot be repaired Cutting the transducer cable will void the warranty and invalidate the European CE mark 2 7 System Connections The connector panel provides the following connection socke...

Страница 23: ...Shift View a zoomed area Zoom Flatten the bottom image to help separate fish from the bottom Bottom Lock Show a real time image of fish and bottom structure directly below the transducer A Scope Chang...

Страница 24: ...ed 2 PresstheFISHFINDERsoftkey Theavailablefishfinderpagelayoutconfigura tions are represented in the next set of soft keys 3 Press the soft key for the page layout you want to view Full Screen Single...

Страница 25: ...ZOOM FISHFINDER SETTINGS FISHFINDER SETTINGS A SCOPE A SCOPE PRESENTATION PRESENTATION BOTTOM LOCK BOTTOM LOCK 200 kHz 48 8ft 20 0 40 60 12nm N UP RM Csr Pos N 26 42 618 W 078 31 961 60 D7939 1 Positi...

Страница 26: ...ZOOM FISHFINDER SETTINGS FISHFINDER SETTINGS A SCOPE A SCOPE PRESENTATION PRESENTATION BOTTOM LOCK BOTTOM LOCK 50 kHz 20 0 40 60 Speed kts 60 50 40 30 20 10 0 68 69 70 71 72 73 74 68 69 70 71 72 73 74...

Страница 27: ...belowtherollingroadtellyouwhatcorrectionisneeded to maintain your course and arrive at the target waypoint Indication arrows are placedeithersideofthesteeringinstruction pointingtowardsthecenterline T...

Страница 28: ...MAN 3 To return to the automatic range adjustment toggle the RANGE soft key to AUTO The default range setting is AUTO This setting is reset at power up Range Shift TheDSMautomaticallyadjuststhedispla...

Страница 29: ...are shown By default the sounder automatically adjusts the gain controls based on depth and water conditions and displays the sharpest possible image Although you can also manually adjust these setti...

Страница 30: ...requency Any adjustments made apply to all windows using that frequency The default is HI Color Gain Color gain determines how echoes of different strengths are displayed As conditions change the colo...

Страница 31: ...e to return to the default display Operating Frequency The DSM provides four frequency modes AUTO mode The system automatically selects the appropriate frequency according to your depth As the depth i...

Страница 32: ...e transducer signal When AUTO is selected default the DSM automatically determines the required power setting based on the current depth speed and bottom signal strength If however youwish to manually...

Страница 33: ...rdfishfinderandazoomedimage 3 Toggle ZOOM FACTOR TO SELECT X2 X3 or X4 for a predefined zoom level The greater the factor the smallerthe area you are viewing andthereforethe smaller thezoombox D8219 2...

Страница 34: ...y This is the default MAN and select ZOOM START You can now use the rotary knob to select the portion of the image to be zoomed 2 Press CANCEL or ENTER to return to the default display Note Selecting...

Страница 35: ...ck image in a single window BOTTOM LOCK OFF to return to the standard fishfinder image 3 ToadjusttherangeoftheBottomLockimage pressB LOCKRANGEandthen use the rotary knob to adjust the range 4 Tore pos...

Страница 36: ...DE 1 in which the image takes up the entire A Scope window MODE2 inwhichonlytheleftsideoftheimagedisplayedinMODE1expands to the entire A Scope window This mode provides the greatest resolution MODE 3...

Страница 37: ...pthvalue andthedetailbelowthebottomremoved Fishnearthe bottom can now be seen more easily Bottom Fill Whenthisfeatureisapplied thedetailbelowthebottomisstretcheddownward The bottom is now clearly defi...

Страница 38: ...re detail which is usefulwhenyouarelookingfor fish If youselecta slowerspeed theinformation remains on the display for a longer time The same section of the bottom is displayed regardless of scrolling...

Страница 39: ...er provides various features to determine depths and distances Depth Digit displays your current depth The size of this digit can be changed via the Fishfinder Setup menu See Depth Digit Sizeon page 4...

Страница 40: ...dard settings at the cursor 1 Sothatitiseasiertopositionthecursoroverthedesiredsite pressPRESENTA TION and then toggle the SCROLL option to PAUSE 2 Maneuver the cursor to the spot on the screen you wo...

Страница 41: ...up 1 Press MENU The main Setup menu is displayed 2 Use the trackpad or the rotary knob to highlight Fishfinder Setup 3 Press the trackpad right to select this item The menu changes to show you the ava...

Страница 42: ...reen Fishfinder Setup Fishfinder Setup Depth Digit Size Depth Lines Palette Depth Offset Speed Calibrate Temp Calibrate DSM Reset Trip Reset Fishfinder Int Rej Second Echo Rej Max Ping Rate Ping Enabl...

Страница 43: ...fers you six different display color combinations You can select the color set for a bold or soft color palette The brightness of the screen can be adjustedoverawiderange suitableforviewingindaylight...

Страница 44: ...displayed speed from 1 to 200 If the reading is too low set Speed Calibration to more than 100 If the reading is too high set Speed Calibrate to less than 100 The default is 100 Temp Calibrate If the...

Страница 45: ...g from the bottom reflecting off the water s surface bouncing off the bottom again and returning once more This option helps eliminate identifying a false bottom Select from the following OFF which of...

Страница 46: ...er Alarms Setup When an alarm is activated press any key to mute the tone Youmaywanttousetheshallowanddeepwateralarmswhenyouareanchored Setthelimitsto justaboveandbelowyour anchordepth The sounder tri...

Страница 47: ...m will sound The depth unit meters feet or fathoms isdependentontheUnitsparametersetintheSystemSetupmenu Changingthe value set for Shallow Range automatically enables the Shallow Alarm Deep Alarm Ifth...

Страница 48: ...eshold for the Temp Alarm If a temperature above this value is detected the Temp Alarmistriggered YoucannotsettheTemp RangeHighsettingtobelower than Temp Range Low Temp Range Low Use therotary knob or...

Страница 49: ...is a sealed unit Maintenance procedures are therefore limited to the following periodic checks Examine the cables for signs of damage such as chafing cuts or nicks Check that the cable connectors are...

Страница 50: ...procedures and replacement parts used will not affect performance There are no user serviceable parts in any Raymarine product Some products generate high voltages so never handle the cables connec to...

Страница 51: ...es Defaultvaluesarelisted in the descriptions for each function To perform the factory reset 1 Press MENU 2 Scroll to and then select FISHFINDER SETUP 3 Scroll to and select DSM RESET A message appear...

Страница 52: ...le and transducer must be replaced as a unit Fishfinder does not dis play fish 1 Fish are not displayed if the boat is stopped targets appear on the display as straight line 2 Ensure the transducer is...

Страница 53: ...tween strings The following table shows the various LED status codes and their meanings 1 After30 seconds ofnonetwork activity the DSM25 enters Standby mode No sonarpings are emitted and no warnings a...

Страница 54: ...net Visit theRaymarineWorld WideWeb siteforthelatestinformationon Raymarine electronic equipment and systems at www raymarine com Customer Support Navigate to the Customer Support page for links to Fi...

Страница 55: ...539 ext 2444 or 1 603 881 5200 ext 2444 Our Technical Support Specialists are available to answer questions about installing operating and trouble shooting all Raymarine products Questions can be sent...

Страница 56: ...Park Portsmouth Hampshire England PO3 5TD Tel 44 0 23 9269 3611 Fax 44 0 23 9269 4642 Technical Support The Technical Services Department handles inquiries concerning installation operation fault dia...

Страница 57: ...ange Storage Range Humidity Waterproof to IPX 7 14 F to 122 F 10 C to 50 C 4 F to 158 F 20 C to 70 C up to 95 at 35 C non condensing Connectors 7 pin transducer 8 pin A65 network Output Power Adjustab...

Страница 58: ...58 DSM25 Owner s Handbook...

Страница 59: ...m 47 Deep Range 47 Depth Digit Size 43 Depth Lines 43 Depth Offset 44 Depths 39 Depth Digit Size 43 Depth Lines 43 Target Depth ID 46 Dimensions 19 Distances 39 Depth Digit Size 43 Depth Lines 43 Targ...

Страница 60: ...1 Presentation 37 Bottom Fill 37 Scroll Speed 38 White Line 37 Problem Solving 52 R Range 28 Range Shift 28 Repair 55 Reset 44 51 Routine Checks 49 S Safety EMC Guidelines 8 Notices 7 Scroll 38 Second...

Страница 61: ...nical Support 55 Temp Alarm 47 Temp Calibrate 44 Temp Range 48 Temperature Graph Page 26 Transducer Cable 22 Cleaning 49 Connections 22 Trip Reset 44 TVG 30 W Warning Codes 53 Warranty 10 63 Waypoints...

Страница 62: ...62 DSM25 Owner s Handbook...

Отзывы: