![Raymarine AXIOM 2 XL Скачать руководство пользователя страница 67](http://html1.mh-extra.com/html/raymarine/axiom-2-xl/axiom-2-xl_installation-instructions-manual_3978554067.webp)
Possible causes
Possible solutions
Damaged cables
1.
Check the unit’s connector for broken or bent
pins.
2. Check that the cable connector is fully inserted
into the unit and that the locking collar is in the
locked position.
3.
Check the cable and connectors for signs of
damage or corrosion, replace if necessary.
4.
With the unit turned on, try flexing the power
cable near to the display connector to see if this
causes the unit to re-boot/loose power, replace
if necessary.
5. Check the vessel’s battery voltage, the
condition of the battery terminals and power
supply cables, ensuring connections are
secure, clean and free from corrosion, replace
if necessary.
6. With the product under load, using a
multi-meter, check for high voltage drop across
all connectors/fuses etc (this can cause the
Sonar applications to stop scrolling or the unit
to reset/turn off), replace if necessary.
Vessel speed too
high
Slow vessel speed and recheck.
Bottom too shallow
or too deep
The bottom depth may be outside of the transducers
depth range, move vessel to shallower or deeper
waters as relevant and recheck.
Poor / problematic image
Possible causes
Possible solutions
Vessel stationary
Fish arches are not displayed if the vessel is
stationary; fish will appear on the display as straight
lines.
Scrolling paused or
speed set too low
Unpause or increase sonar scrolling speed.
Possible causes
Possible solutions
Sensitivity settings
may be inappropriate
for present
conditions.
Check and adjust sensitivity settings or perform a
Sonar reset.
Damaged cables
1.
Check the unit’s connector for broken or bent
pins.
2. Check that the cable connector is fully inserted
into the unit and that the locking collar is in the
locked position.
3.
Check the cable and connectors for signs of
damage or corrosion, replace if necessary.
4.
With the unit turned on, try flexing the power
cable near to the display connector to see if this
causes the unit to re-boot/loose power, replace
if necessary.
5. Check the vessel’s battery voltage, the
condition of the battery terminals and power
supply cables, ensuring connections are
secure, clean and free from corrosion, replace
if necessary.
6. With the product under load, using a
multi-meter, check for high voltage drop across
all connectors/fuses etc (this can cause the
Sonar applications to stop scrolling or the unit
to reset/turn off), replace if necessary.
Transducer location
• Check that the transducer has been installed in
accordance with the instructions provided with
the transducer.
• If a transom mount transducer is mounted too
high on the transom it may be lifting out of the
water, check that the transducer face is fully
submerged when planing and turning.
Transducer
kicked-up
If the transducer has a kick-up mechanism, check
that it has not kicked up due to hitting an object.
67
Содержание AXIOM 2 XL
Страница 2: ......
Страница 4: ......
Страница 22: ...CHAPTER 5 PRODUCT DIMENSIONS CHAPTER CONTENTS 5 1 Product dimensions page 23 22...
Страница 39: ...CHAPTER 9 POWER CONNECTIONS CHAPTER CONTENTS 9 1 Power connection page 40 Power connections 39...
Страница 56: ...CHAPTER 13 AUDIO CONNECTIONS CHAPTER CONTENTS 13 1 Audio RCA connections page 57 56...
Страница 95: ...RayNet to RJ45 and RJ45 SeaTalkhs adapter cables Spares and accessories 95...
Страница 102: ......
Страница 106: ...Video app HDMI IN 50 Video connection 50 W Warranty 11 73 WEEE Directive 11 What s in the box 21...
Страница 107: ......