武汉锐科光纤激光技术股份有限公司
WUHAN RAYCUS FIBER LASER TECHNOLOGIES CO. LTD.
6
CAUTION: The fiber optic cable and output head are precise
opticinstrument, ANY vibration or impact to the output head, and
twist orexcessive bend to the cable will damage the instrument.
2.4 Operation Environment
Table 1: The Operation Conditions for the Laser
Installation Environment
Flat and no vibration
Ambient Temperature
0℃~40℃
Relative Humidity
<70%
It is recommended to install the product in an environment with air
conditioning.
2.5 Precautions for Use
a) Make sure the instrument is properly grounded before you use it;
b) Make sure that the correct voltage of 24VDC power source is used.
Failure to connectpower source correctly will damage the device;
c) There are no user serviceable parts, equipment or assemblies inside
the product. All serviceand maintenance shall be performed by
qualified Raycus personnel. In order to preventelectric shock,
please do not break the seal or uncover the shield. Failure to comply
withthis instruction will void the warranty;
d) Please inspect the output head carefully for dust or other
contamination. Use appropriatelens paper to clean it if necessary.
Do not touch the output lens at any time;
e) Please cap the output head when it is not in use, and make sure the
cap is clean;
f) It is not allowed to install the output head when the laser is in
operation;
g) Do not look into the output head directly. Wear appropriate
protective eye glasses all thetime when operating the laser;
h) Failure to follow the instructions may cause malfunction and damage
to the device, suchdamage is not covered by warranty.