Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C4000XZ~12000XZ
30
Turn off red light: Send "ABF" by communication
,
or click
button on
the host computer software
13
The communication sends "SDC XX" to set the power percentage, XX represents the power
percentage, or click
button on the host
computer software
5.1 ON Mode
In the On Mode, the user can send commands to set different working mode through computer
software or direct communication. After the laser is powered on again, the mode before power failure
will be memorized.
5.2 AD Enable Mode
When AD mode is enabled, the laser power is determined by the analog voltageof pin 1 and pin 4 of
XP4. If the AD mode is not enabled, the laser power can be set through the computer software or send
the “SDC XX” command.
5.3 Emisson External Control Enable
When the emission external control is enabled, the laser emission is determined by the level
differencebetween the pins of MOD+, MOD- in the XP2 port; if the emission external control is not
enabled, thelaser emission or shutdown are determined by the emit button in the Raycus Laser
Control System. Also, you can send “EMON” command to turn laser emission on, and send “EMOFF”
command to turn laser emission off.
5.4 Guide Laser (Red Guide Beam) Control
In “ON” mode guide laser can only be turned on/off by using Raycus Laser Control System, or
bysending command of “ABN” (on) / “ABF” (off).
The red light module inside the laser works through communication, so there is a time delay of
at least 10ms for the opening and closing of red light
;
When the red light is on, the laser cannot be set to “Ready”. Only after the red light is turned off
the laser can be set to “Ready”. (This limit can be changed, please contact Raycus Engineer).