4.7.2 Logmenu

Display all alarm and fault information of the current laser on the log

menu.

Figure 10 Raycus software log menu

4.7.3

About

Menu

The laser time, model, serial number, main control serial number, key version number and

system information are displayed in the about menu, and the Raycus software reads it once from
the main control module when the

About

menu is opened.

Содержание RFL-C2000S-HP

Страница 1: ...1 Continuous Wave Fiber Laser User Guide RFL C2000S HP RFL C3000S HP RFL C4000S HP RFL C6000S HP Wuhan Raycus Fiber Laser Technologies Co Ltd...

Страница 2: ...Installation 11 3 1 Dimensions 11 3 2 Size and installation of output optical cable 12 3 3 Cooling system installation and requirements 12 3 4 Installation considerations 15 4 Guiding 16 4 1 Front pan...

Страница 3: ...er Laser Technologies Co Ltd User Guide RFL C2000S HP RFL C6000S HP 3 6 Warranty Return and Maintenance 56 6 1 General Warranty 56 6 2Limitations of Warranty 56 6 3Service and Repair 57 6 4 Scrapping...

Страница 4: ...sible laser radiation at or around a wavelength of 1080 nm and the total light power radiated from the optical output is greater than 300W 6000W depending on model Direct or indirect exposure of this...

Страница 5: ...put head warning product certification and product nameplate The detailed description of the security identifier is as follows Table 1 Specifications of Safety Labels English Label Chinese Label Engli...

Страница 6: ...injury for operators b Make sure that the correct voltage of the DC power source is used Wrong wiring mode or power supply voltage will cause an irrecoverable damage to the laser device 1 6 Other Safe...

Страница 7: ...odulation frequency and editable waveform Applications Welding 5G Infrastructure 3D printing Laser research Applications Welding 5G Infrastructure 3D printing Laser research 2 2 Package accessories Pl...

Страница 8: ...e listed as the following table Table 2 Laser operation environment Model RFL C2000S HP RFL C3000S HP RFL C4000S HP RFL C6000S HP Power Voltage V 360 510V AC 50 60Hz Power Capacity kVA 7 5 11 5 15 22...

Страница 9: ...d areas dew point temperature is higher than 22 more than laser cooling water temperature 22 will produce condensation measures must be taken prior to use Measure 1 see Section 4 2 Access clean and dr...

Страница 10: ...wer Output Power Instability 1 5 Nominal Output Power Duration 2h Operating Temp 22 1 Modulation Frequency Hz 1 5 000 Red Guide Laser Power mW 0 5 1 Output Characteristics BPP mm mrad 3 4 Nominal Outp...

Страница 11: ...HP RFL C3000S HP RFL C4000S HP RFL C6000S HP 11 3 Installation 3 1 Dimensions Figure 2 shows the external dimensions of the RFL C2000S HP RFL C3000S HP RFL C4000S HP RFL C6000S HP take C4000S as an e...

Страница 12: ...the size of the protective end cap The protective end cap of this type is lengthened Figure 3 Dimensional drawing of QBH output optical cable unit mm Before installing the output cable in the process...

Страница 13: ...ith pure water 3 When the ambient temperature around the equipment is between 10 C and 0 C an ethanol solution with a volume ratio of 30 must be used and changed every two months 4 When the ambient te...

Страница 14: ...em and joints should be checked for leaks The external water pipes must be installed and connected according to the water inlet IN and water outlet OUT marked on the laser otherwise the laser may not...

Страница 15: ...installation or operation of the laser for the time being f Do not step on squeeze or excessively bend the yellow metallic armoured protective sleeve during installation of the output cable to avoid...

Страница 16: ...eep the protective cap on the output head in a safe place to prevent it from being contaminated otherwise indirect contamination of the output head will occur when the cap is closed 4 Guiding Please u...

Страница 17: ...Emission indicator laser out light Laser red light on 2 POWER Control power indicator white light indicates that the control system is on 3 ALARM Alarm indication when the yellow light is on it means...

Страница 18: ...trol of the laser and storage of alarm information 7 CTRL INTERFACE Control interface CTRL INTERFACE interface 24 pin multi functional multiplex port which allows the user to set the control mode inpu...

Страница 19: ...00S HP Power Supply 360 510VAC50 60Hz Power Cable End of Cable Four strands of wire diameter 4 mm2 Labelled L1 L2 L3 and PE Descriptions L1 L2 L3 Phase line PE Protective earth wire Remarks The plug a...

Страница 20: ...nsmit Data 6 RS232Rx Receive Data 7 RS232Com Return RS 232 Return 8 Remote Key Switch Contact Closure Input 24Vdc 1A Contact s and cables 20s Starts the internal main control board power supply Passiv...

Страница 21: ...sion ON Digital Output 24Vdc 100mA 100us High indicateslaser is emitting Please check the level of the control signal to ensure that it meets the requirements The laser may be damaged if the voltage e...

Страница 22: ...ion 1 TX Data transmission 2 TX Data transmission 3 RX Data reception 4 N C Noconnection 5 N C Noconnection 6 RX Data reception 7 N C Noconnection 8 N C Noconnection If conditions permit please give p...

Страница 23: ...P Settings on PC Side After the IP setting is completed open the Raycus software and the connection status in the corresponding text box on the Raycus softwaremenu shows connected indicating that the...

Страница 24: ...o parity bit and no flowcontrol Ethernet port configuration as below Laser default IP address 192 168 0 10 Laser TCP port 10001 Laser UDP port 8099 4 4 3 2 Laser communication protocol network port se...

Страница 25: ...ment Contents and Command Examples of Laser Command Description Command Example ABF Aiming Beam OFF Turn off red beam Send ABF r Return ABF r ABN Aiming Beam ON Turn on red beam Send ABN r Return ABN...

Страница 26: ...Working in continuous mode SPRR Set Pulse Repetition Rate Send SPRR 1000 r Return SPRR 1000 r Other return value ERR input Err r Input frequency 0 ERR Out of Range r Exceeds the maximum pulse width ra...

Страница 27: ...RIP r Return RIP 192 168 0 10 r RMASK Read Sub net Mask Read the current sub net mask address Send RMASK r Return RMASK 255 255 255 0 r SIP Set IP Set LaserIP Send SIP 192 168 0 10 r Return SIP 192 1...

Страница 28: ...n that Bits2 and 12 have been set That means Laser Enable is turned on and Modulation mode is enabled 1 Authorization time Bit 1 0 Normal 1 Overheat Bit 2 0 Laser not enabled 1 Laser enabled Bit 3 0 B...

Страница 29: ...low rise and slow drop mode ON Bit 21 0 The laser operates in ON mode 1 The laser operates in REM mode Bit 22 0 Programming mode off 1 Programming mode on Bit 23 Reserved Reserved Bit 24 0 Normal 1 Lo...

Страница 30: ...ter pipe e Connect the control circuit and power supply according to the control mode 4 6 Steps of Starting a Make sure the air switch is OFF all electrical connections must be finished before the las...

Страница 31: ...er cooled plate temperature of the laser in degrees Celsius Power indicator Indicates the current status of the main power supply Green main power is on Gray main power is off Ready indicator Indicate...

Страница 32: ...not meet logical requirements Program Mode Green The laser is running in programming mode Gray The laser is not running in programming mode Ramp Control Green the laser is running in power ramp up and...

Страница 33: ...m and fault information of the current laser on the log menu Figure 10 Raycus software log menu 4 7 3 About Menu The laser time model serial number main control serial number key version number and sy...

Страница 34: ...menu you can set the language used by the software After selecting the language and clicking OK the software will automatically convert the content displayed in the software to the language without r...

Страница 35: ...ine code laser lock time and lock time are loaded once The laser lock time is Raycus time limited lock for integrators and the lock time is for integrators to end customers time limited lock On the au...

Страница 36: ...rol mode The control mode adds the function of the operable control menu on the basis of the observation mode A password is required to enter the control mode The initial password is 81338818 the pass...

Страница 37: ...status information menu Connect to the network through the main control module system parameter menu AP mode the laser is a WiFihot spot hot spot name and password can be configured after the mobile...

Страница 38: ...RFL C3000S HP RFL C4000S HP RFL C6000S HP 38 Figure 15 Main control module system parameter menu 4 7 8 ACDC module The ACDC module page contains the relevant status information of the ACDC module and...

Страница 39: ...FL C2000S HP RFL C3000S HP RFL C4000S HP RFL C6000S HP 39 Figure 16 ACDC module menu 4 7 9 DCDC module The DCDC module page contains the relevant status information of the DCDC module and the refresh...

Страница 40: ...pin analog voltage 0 10V 0V 0 10 100 OFF The Raycus software sets the power percentage or the communication command SDC setting b External enable Table 15 External enable settings External enable Lase...

Страница 41: ...HP 41 ON The Positive edge of pins 15 and 16 of INTERFACE 24 pins OFF The laser emission button or communication command of the Raycus software EMON EMOFF 4 8 1 Full external control mode control mode...

Страница 42: ...re 19 Control Timing Diagram 4 9 Red guide beam control Table 17 Red guide beam external control mode Red guide beam external control ON 17 pin of INTERFACE Positive edge turn on the red guide beam Ne...

Страница 43: ...e rise and fall parameters are 0 the rise and fall mode will be automatically turned off After the slow rise and fall mode is turned on the laser performs the ramp up program to the target power accor...

Страница 44: ...0 the laser is running in programming mode Please use the Raycus software provided by Raycus to edit the waveform and select the pre running program number The output waveform of the laser is determi...

Страница 45: ...Wuhan Raycus Fiber Laser Technologies Co Ltd User Guide RFL C2000S HP RFL C3000S HP RFL C4000S HP RFL C6000S HP 45 Figure 22 Check the display programming mode menu Figure 23 Programming mode menu...

Страница 46: ...L C6000S HP 46 4 11 3 View the number of waveform Figure 24 View the number of waveform bars Click the Refresh program list button the software will automatically list the number of waveform that have...

Страница 47: ...de RFL C2000S HP RFL C3000S HP RFL C4000S HP RFL C6000S HP 47 4 11 4 View waveform content Figure 25 View waveform content Click the waveform number to be read with the left mouse button and the progr...

Страница 48: ...00S HP RFL C3000S HP RFL C4000S HP RFL C6000S HP 48 4 11 5 Clear all waveform Figure 26 Clear the waveform Click the program number that needs to be cleared click Clear and then click Write to Laser t...

Страница 49: ...Ltd User Guide RFL C2000S HP RFL C3000S HP RFL C4000S HP RFL C6000S HP 49 4 11 6 Edit waveform First left click on the pre edited waveform number Figure 27 Edit waveform Select Command under Command T...

Страница 50: ...echnologies Co Ltd User Guide RFL C2000S HP RFL C3000S HP RFL C4000S HP RFL C6000S HP 50 Figure 28 Select command The command just now appears in the program list on the left After editing all the com...

Страница 51: ...number it will show that the read is successful 4 11 7 Command interpretation Table 19 detailed explanation of waveform command word Command code 1 byte Parameter 1 2 bytes Parameter 2 4 bytes Descri...

Страница 52: ...mber of times to jump to that row The number of times the loop jumps to the line number 6 EXTPower 1 0 10V 4 12 Steps of close Turn off the lasers in the following orders a Turn off the laser b Discon...

Страница 53: ...is abnormal the condensation is abnormal the flow is abnormal etc Figure 30 The main menu of the Raycus software When the laser is running any alarm occurs except for the Interlock abnormality the Ray...

Страница 54: ...orking normally whether the water connection is abnormal etc When the water cooling system is working normally and the water temperature drops below 30 C please restart the laser to try In the case of...

Страница 55: ...y of the laser exceeds the set value the scattered light alarm is generated and the laser light output function is locked not unlockable Scattered light alarms only occur when the laser is emitted Pos...

Страница 56: ...r or replace any product that proves to be defective in materials and workmanship selectively during the warranty period Only products with particular defects are under warranty Raycus reserves the ri...

Страница 57: ...by Raycus otherwise Raycus will have the right not to repair any product damage caused by the package When you receive Raycus products please check whether the products are intact and undamaged in tim...

Отзывы: