4.5 Laser installation sequence
a) Take out the lasercarefully and move it to the installation position;
b) Remove the protective cap of the outputcable head, and use strong light to check
whether the lens at the output end has dust. If yes, please clean it before installation, and
then cover the protective cap of the output head;
c) Install the output cable on the processing equipment according to the actual situation
(install the cooling water pipe of the output headat the same time), pay attention to
sorting out the output optical cable, and protect the output head. Remove the protective
cap, confirm whether the lens at the output end is clean again, and then install the output
head;
d) Connect the cooling system, water inlet filter assembly and laser cooling water pipe;
e) Connect the control circuit and power supply according to the control mode.
4.6 Steps of Starting
a) Make sure the air switch is OFF,all electrical connections must be finished before the
laser is powered on
;
b) Short the 1/4, 2/3 pins of CTRL-INTERFACE
;
c) Turn on the chiller and check leakage. If there is no water leakage, turn off the chiller
and wait for the laser to turn on
;
d) Turn on the air switch on the rear panel
;
e) Turn on the chiller
;
f) Short the 8/9 pins of CTRL-INTERFACE and start the laser.
4.7 Functions of Raycus software
The RFL-C2000S-HP/ RFL-C3000S-HP/ RFL-C4000S-HP/ RFL-C6000S-HP Raycus
software communicates with the main control board through UDP when it is working. Through
the background program running in the software and the human-computer interaction operation,
the laser parameters are read and set and the control functions are realized. The menu displayed
by the software is divided according to functional categories, including control, alarm, about,
language selection, authorization, working mode selection and other pages.
4.7.1 The control menu