Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C15000TZ
27
B7
Feedback
signal of A1
Output
signal
The laser has received the A1 signal when B7 is
high.
B8
Main power
supply of
laser
Output
signal
The main power of laser is on when B8 is high.
B9
Program
running
Output
signal
Laser program is running when B9 is high.
B10
Program
ending
Output
signal
Laser program is ended when B10 is high. B10
clears when the A2 is invalid.
B11
Abnormal
Wave Mode
Termination
Output
signal
Laser program is ended abnormally when B11 is
high. B11 can be cleared when the A4 is high.
B12
Synchronous
output
Output
signal
Sync signal output in programming mode.
B13
Warning
output
Output
signal
Laser is warning when B13 is high.
B14
Not connect
B15
External
power supply
(Positive
pole)
Input
signal
The 24 V input voltage, power supply of all XP1
output signal. Only when B15 and B16 access 24
V power, output signal is effective.
B16
External
power
(Negative
pole)
Input
signal
Indicate the current optical gate channel:
0000-all optical gate channels closed;
0001-channel1 opened;
0010-channel 2 opened;
0011-channel 3 opened.
D1 is the lowest bit, D4 is the highest bit.
(For lasers with optical gate channels only, these
pins are spare in other lasers)
D1~D4
Current
optical gate
channel
Output
signal
D5
Not connect
D6