Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C15000TZ
6
c) Please cap the output head when it is not in use. Do not touch the output lens at any time. Use
appropriate lens paper to clean it if necessary.
d) Safety keep the cap when using the laser. To avoid dust, make sure the opening direction of the
cap is put down.
e) Failure to follow the instructions may cause laser power loss, such loss is not covered by
warranty.
2.6. Specifications
Table 2 Product Specifications
Optical properties
Test Conditions
Model
C15000TZ
Output Power(kW)
15
/
Operation Mode
CW/Modulated
/
Polarization State
Random
/
Output Power Tunability
(%)
10
~
100
/
Emission Wavelength(nm)
1080±5
Nominal Output Power
Output Power Unstability
±1.5%
Nominal Output Power; Duration:
5hrs; Ambient Temp.: 25℃
Modulation Frequency (Hz)
50
~
2k
Nominal Output Power
Red Guide Laser
Power(mW)
0.5
~
1
/
Fiber output Types
QP
/
Beam Quality
(BPP, mm•mrad)
<
4
Nominal Output Power
Fiber core diameter
(μm)
100
customizable
Delivery Cable Length(m)
20
customizable
Electrical characteristics
Operating Voltage
Three-phase four-wire system
AC340V~AC420V
、
50/60Hz
(
Include PE
)
/
Maximum power
Consumption (kW)
45
/
Control Method
Serial communication / AD
/
Other characteristics
/
Dimension
WxHxD
(
mm
)
960x1500x1160
(
mm
)
Includes casters and rings, without
warning lights
Weight (kg)
<
700
Air conditioning included
Operating Ambient
Temperature (°C)
10
~
40
/
Humidity (%)
<
70
/
Storage Temperature (°C)
-10
~
60
/
Cooling Method
Water cooling
/