Wuhan Raycus Fiber Laser Technologies Co., Ltd
User Guide RFL-A2000D-3000D Ver.1.0
32
For 60% output power, type in 60.
If you input a value out of the range specified in the brackets, the system will instruct you
again to input a legal value. Just follow the instructions.
When the parameters are set and laser emission is enabled (“LASER” on front panel is
pressed down or “LAS_C” is high), the laser emits sequence of pulses you have customized. The
“MODULATION” cable is also left disconnected in this mode.
CW mode with remote modulation and Pulse mode with remote modulation
Press “3” in the mode selection page to enter “CW mode with remote modulation”, and
press “4” to enter “Pulse mode with remote modulation”. In these two operation modes, the
parameter settings are no different from “CW mode” and “Pulse mode”. Only one more emission
condition is added-remote modulation signal. So you must connect the “MODULATION” cable
to remote modulation signal. Notice that the modulation signal is 24V level, and active high.
When the parameters are set, laser emission is enabled (“LASER” on front panel is pressed
down or remote emission control is sent from “LAS_C”), and the remote modulation signal
inputs from “MODULATION”, the laser emits.
Clear errors
Press “5” in the mode selection page will clear error records. Then press “7” to return.
Error records are cleared
Press ‘7’ to return to previous menu
Save system configurations
This operation is for Raycus personnel only.
4.8 RS-232 Mode
RS-232 mode is a remote control mode. In this mode, we have a protocol for
communication between the laser and the upper computer, and you can set emission parameters
and return errors. Notice that the “LASER” button or “LAS_C” is of no use in this mode, but
make sure to keep the button up and left “LAS_C” disconnected.