The present operation mode is CW mode
Please set percentage of output power (MIN=0, MAX=100), press ‘Enter’ to confirm:
Then type a number between 10 and 100, with minimum increment of 1, then press “Enter”.
For example, type “20” and enter, the output power will be set to approximate 20%.
Please set percentage of output power (MIN=0, MAX=100), press ‘Enter’ to confirm:20
Press ‘7’ to return to previous menu, press ‘Enter’ to reset
If you don’t input anything, the system will accept 0 as the default, which means that if you
press “Enter” without no value typed in, the percentage of output power will be set to 0%.
When the percentage of output power is set and laser emission is enabled (“LASER” on
front panel is pressed down or “LAS_C” is high), the laser emits. The “MODULATION” cable
is disconnected in this mode.
You can press “Enter” again to set another value for percentage of power, or press “7” to
return to previous menu to choose another operation mode.
Pulse mode
Press “2” in the mode selection page, you will enter “Pulse mode”. You should provide 3
parameters for this operation-repetition frequency, duty cycle and percentage of output power.
For example, set the repetition frequency to 2kHz, duty cycle to 50% and percentage of
output power to 60%.
The present operation mode is pulse mode
Please set repetition frequency (MIN=50, MAX=5000), press ‘Enter’ to confirm: 5000
Please set duty cycle (MIN=0, MAX=100), press ‘Enter’ to confirm: 50
Please set percentage of output (MIN=0, MAX=100), press ‘Enter’ to confirm:60
Press ‘7’ to return to previous menu, press ‘Enter’ to reset
The repetition frequency is between 50Hz and 5 kHz, but you must input a number between
50 and 5000, so for 5 kHz, input 5000;
Duty cycle is between 0% and 100%, for 50%, type in 50;