15
Floor sensor calibration
The temperature of the floor surface can differ from the temperature measured by the floor
sensor due to the floor construction, the floor type and the position of the floor sensor. In order
to calibrate your thermostat to this difference you can use the floor sensor calibration OFFSET in
installer Menu 4.
After the temperature on the floor is stabilized, place a thermometer on the floor surface in order to
sense the real temperature on the surface (Tsurface). Read the floor sensor temperature (Tsensor)
on the thermostat and adjust the OFFSET accordingly to the formula:
T
sensor
T
surface
OFFSET = Tsensor - Tsurface
Room sensor calibration
If the value measured by the room sensor in the thermostat differs from the real room
temperature, it is possible to calibrate the room sensor using the installer Menu 5.
After the temperature in the room is stabilized, place a thermometer close to the wall in order
to sense the real room temperature. If this value differs from the one shown by the thermostat,
adjust Menu 5 using the “ ” or the “ ” until the thermostat shows the same value as the reference
thermometer.