14
#
Description
Range
Default setting
7
Maximum temperature
set point for the
Floor Sensor
Floor sensing mode: Minimum
temperature set point floor
sensor (installer menu 6)
+5°C .. 35°C
Room sensing mode: OF
Room sensing mode with floor
temperature limiter: 10 .. 35°C
35°C
OF
27°C
8
Minimum temperature
set point for the Room Sensor
Floor sensing mode: OF
Room sensing mode: 5 .. 15°C
Room sensing mode with floor
temperature limiter: 5 .. 15°C
OF
5°C
5°C
9
Maximum temperature
set point for the Room Sensor
Floor sensing mode: OF
Room sensing mode: Minimum
temperature set point room
sensor (installer menu 8)
+5°C .. 40°C
Room sensing mode with floor
temperature limiter: Minimum
temperature set point room
sensor (installer menu 8)
+5°C .. 40°C
OF
40°C
40°C
10
Adjustable hysteresis
0.5 .. 2.0°C