background image

14

#

Description

Range

Default setting

7

Maximum temperature 
set point for the  

Floor Sensor

Floor sensing mode: Minimum 

temperature set point floor  

sensor (installer menu 6) 

 +5°C .. 35°C

Room sensing mode: OF

Room sensing mode with floor 

temperature limiter: 10 .. 35°C

35°C 
 
 
 

OF

27°C

8

Minimum temperature 
set point for the Room Sensor

Floor sensing mode: OF

Room sensing mode: 5 .. 15°C

Room sensing mode with floor 

temperature limiter: 5 .. 15°C

OF

5°C

5°C

9

Maximum temperature 
set point for the Room Sensor

Floor sensing mode: OF

Room sensing mode: Minimum 

temperature set point room  

sensor (installer menu 8)

 +5°C .. 40°C

Room sensing mode with floor 

temperature limiter: Minimum 

temperature set point room  

sensor (installer menu 8)  

+5°C .. 40°C

OF

40°C 

 

 

 

40°C

10

Adjustable hysteresis

0.5 .. 2.0°C

1.0°C

Содержание green leaf

Страница 1: ...GREEN LEAF EU PROGRAMMABLE THERMOSTAT FOR ELECTRICAL FLOOR HEATING INSTALLATION INSTRUCTION pentairthermal com manuals THERMAL BUILDING SOLUTIONS EN RaychemGreenLeafEU IM EU0637 Rev0 Full EN Manual ...

Страница 2: ... 6 INSTALLER MENU 17 7 TROUBLESHOOTING 21 8 TECHNICAL SPECIFICATION 22 ATTENTION This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not...

Страница 3: ...est possible comfort and the lowest possible energy usage The Thermostat can work in 3 different temperature sensing modes Floor Sensing mode Room Sensing mode Room Sensing mode with floor temperature limiter The Thermostat has 2 programmes to choose from Manual ON OFF Constant Single temperature Timer programme 4 timer events day To change from one programme to the other just touch the intelligen...

Страница 4: ...r flush mounting in a wall box It should be positioned approximately 1 5 meters above the floor protected from direct sunlight and draughts All electrical conduits passing into the wall box that contain cables must also be sealed to protect the thermostat against draughts e g with a piece of insulation in the conduit outlet Step 1 Switch off the power supply Step 2 Detach the metallic support from...

Страница 5: ... floor surface Do not position the floor sensor tip closer than 3 cm to the heating cable The floor sensor cable can be extended up to 100 m with a separate standard installation cable 2 x 1 5 mm2 230VAC Step 5 Connect the electrical power supply the sensor and the cold lead of the electrical floor heating system to the Green Leaf according to the electrical diagram If you connect heating cables e...

Страница 6: ...device L N L1 1 2 3 4 5 6 L2 L3 PE N N N N L L L PE A1 A2 K1 Power supply 230 VAC K1 contactor with integrated suppression device 10KΩ SENSOR SENSOR NTC Floor Sensor Heating cable 230 VAC Max 13A Power supply 230 VAC Direct connection e g single heating circuit Max 13A for constant wattage cable Max 10A for self regulating cables 10KΩ N L L N PE PE PE NTC Floor Sensor Power supply heating cables C...

Страница 7: ... T2Red Self regulating heating cables have an inrush current when the floor is cold In order to guarantee the life time of the thermostat the maximum load of the self regulating application in nominal conditions is limited to 10A A 13A self regulating load will reduce the life time of the relay contacts 3 USING THE THERMOSTAT The Display Display in manual on off programme The following icons are v...

Страница 8: ...temperature limiter mode Actual room temperature on the display Remark When pushing on the or button the set point temperature appears on the display blinking for 5 seconds Installer Menu Touch the M button for 5 seconds to enter the Installer Menu Display in timer programme The following icons are visible in the Timer Programme Time and day The actual day is displayed on the screen with the 3 let...

Страница 9: ...start in MANUAL ON OFF programme using the floor sensing mode as a standard see INSTALLER MENU to change the sensing mode You will see the following screen Touch or to show the set point temperature It will blink for 5 seconds 1 Touch to decrease the temperature 2 Touch to decrease the temperature To switch from Manual ON OFF to Timer Programme touch the button once To switch off the thermostat to...

Страница 10: ...6 25 20 15 10 5 0 0 0 0 1 0 0 2 0 0 3 0 0 4 0 0 5 0 0 6 0 0 7 0 0 8 0 0 9 0 0 1 0 0 0 1 1 0 0 1 2 0 0 1 3 0 0 1 4 0 0 1 5 0 0 1 6 0 0 1 7 0 0 1 8 0 0 1 9 0 0 2 0 0 0 2 1 0 0 2 2 0 0 2 3 0 0 0 0 0 1 0 0 2 0 0 3 0 0 4 0 0 5 0 0 6 0 0 7 0 0 8 0 0 9 0 0 1 0 0 0 1 1 0 0 1 2 0 0 1 3 0 0 1 4 0 0 1 5 0 0 1 6 0 0 1 7 0 0 1 8 0 0 1 9 0 0 2 0 0 0 2 1 0 0 2 2 0 0 2 3 0 0 25 20 15 10 5 0 MON TUE WED THU FRI SA...

Страница 11: ...ouch the button to validate Remark In case of battery drainage after long period of power failure you might have to re programme the clock 5 PROGRAMMING THE TIMER PROGRAMME Touch the button for 3 seconds to program the Timer Programme Touch or to choose the day or the sequence of days you want to program Touch the button to validate Day Sequences are MON TUE WED THU FRI SAT SUN MON TUE WED THU FRI...

Страница 12: ...ouch or to change the temperature for Event 1 Touch the clock button to validate For Event 2 3 and 4 Repeat the actions for event 1 for the Events 2 3 and 4 Touch the button at any time during the programming to save your changes and return to the Timer Programme If needed you can repeat the complete procedure to program other days or sequences of days ...

Страница 13: ...12 vs 24 hours display 12 24 24 3 Motion sensor When getting close to the thermostat 5cm range the display lights up automatically ON OF ON 4 Offset for floor sensor calibration Offset of 0 10 C 4 C 5 Room sensor calibration Measured sensor temperature 5 C Measured sensor temperature 6 Minimum temperature set point for the Floor Sensor Floor sensing mode 5 15 C Room sensing mode OF Room sensing mo...

Страница 14: ...perature set point for the Room Sensor Floor sensing mode OF Room sensing mode 5 15 C Room sensing mode with floor temperature limiter 5 15 C OF 5 C 5 C 9 Maximum temperature set point for the Room Sensor Floor sensing mode OF Room sensing mode Minimum temperature set point room sensor installer menu 8 5 C 40 C Room sensing mode with floor temperature limiter Minimum temperature set point room sen...

Страница 15: ...re on the surface Tsurface Read the floor sensor temperature Tsensor on the thermostat and adjust the OFFSET accordingly to the formula Tsensor Tsurface OFFSET Tsensor Tsurface Room sensor calibration If the value measured by the room sensor in the thermostat differs from the real room temperature it is possible to calibrate the room sensor using the installer Menu 5 After the temperature in the r...

Страница 16: ... floor sensor can be replaced by a new In the event of malfunction of the room sensor the entire thermostat must be replaced Error 3 or Error 4 Error 5 occurs if the thermostat is set in Room Sensing Mode and the floor sensor is installed To resolve the error change the sensing mode in Floor sensing or Room sensing with floor temperature limiter Otherwise remove the floor sensor to work in room se...

Страница 17: ... 0 5 2 0 C Control modes Floor sensing Room sensing Room sensing with floor temperature limiter Temperature control Manual ON OFF Timer programme Protection class IP 20 Terminals Max 2 5 mm Floor sensor with 3 m cable NTC 10KΩ 25 C Maximum length of floor sensor Cable 100 m 2 x 1 5 mm 230VAC cable type Approvals Type of action 1 B 39 Control pollution degree 2 49 Rated impulse voltage 4kV 75 Tempe...

Страница 18: ...18 ...

Страница 19: ...19 86 3 86 3 48 0 86 3 49 0 79 8 60 0 16 5 41 0 Dimensions ...

Страница 20: ... Fax 39 02 577 61 55 28 salesit pentair com LIETUVA LATVIJA EESTI Tel 370 5 2136633 Fax 370 5 2330084 info baltic pentair com MAGYARORSZÁG Tel 36 1 253 7617 Fax 36 1 253 7618 saleshu pentair com NEDERLAND Tel 0800 0224978 Fax 0800 0224993 salesnl pentair com NORGE Tel 47 66 81 79 90 Fax 47 66 80 83 92 salesno pentair com ÖSTERREICH Tel 0800 297410 Fax 0800 297409 info ptm at pentair com POLSKA Tel...