Because this appliance uses a pre-mix burner. No setting
up of combustion is required, the burner automatically
controls the air to gas rate ratio.
IMPORTANT:
Ensure that the bottom louvered plinth is in
place during combustion testing and setting procedures.
Ensure the outer door is closed.
Turn the burner on.
After 15 minutes, lift up the RH insulating cover and
remove the countersunk screw and insert the sensing end
of a portable indicator to check the CO
2
(Carbon Dioxide)
level.
CO
0 - 50 ppm
CO
2
8.2% - 9.9% (Natural Gas)
CO
2
10.3% - 10.7% (Propane)
If these volumes cannot be obtained, check the gas rate,
adjust throttle screw if required and allow reading to
stabilise.
SETTING COMBUSTION
Installation requirements
15