SEE FIG. 37
Follow instructions in sections BURNER ACCESS, Steps
1 to 3, BURNER REMOVAL, Steps 1 to 5 .
1.
Remove plug.
2.
Remove solenoid securing nut and washer.
3.
Remove solenoid coil.
4.
Fit new solenoid coil, re-assemble in reverse
order.
SEE FIG. 38
Follow instructions in sections BURNER ACCESS, Steps
1 to 3, BURNER REMOVAL, Steps 1 to 2.
1. Remove 2 control box mounting screws.
2. Insert a flat bladed screwdriver in LH side of c.box as
diagram.
3. Repeat as above for RH side.
4. Gently pull c. box away from base.
5. Fit new c. box, re-assemble in reverse order.