SEE FIG. 9
5.
Clean the boiler outlet flueway by inserting the flexible
brush through the rear aperture, directing it towards
the flue outlet. Scrape the deposits towards the heat
exchanger.
6.
Thoroughly clean boiler heat exchanger flueway.
7.
Carefully vacuum any debris that has fallen down into
the burner chamber.
8.
Clean and replace boiler flueway baffles in reverse
order. Locate boiler flue access door, secure.
9.
Replace insulation pad.
SEE FIG. 10 & 11
1.
Remove the top oven door and place in a safe
position.
2.
Remove base access door using hex. driver.
3.
Thoroughly clean top, side and base flueways through
access apertures with brush.
4.
Remove all debris with vacuum cleaner.
5.
Replace base access door. Secure in position using
hex. driver.
6.
Brush and clean in between hotplate ribs on
underside.
7.
Examine soft rope seal located around hotplate
aperture in top plate. Replace if frayed or damaged.
8.
Replace hotplate ensuring the underside ribs lie over
the boiler, and that it seals to the top plate.
8
Cleaning
FIG. 9
FIG. 10
FIG. 11
DESN 514431
DESN 514437
DESN 514436
OVEN & HOTPLATE FLUEWAY
CLEANING
Содержание Heatranger 8120K
Страница 27: ...26 Fault Finding FIG 46 Appliance Control Panel Internal Wiring ...
Страница 28: ...27 Fault Finding Burner Control Wiring FIG 47 ...
Страница 32: ...31 ...