LIGHTING
Lighting instructions can also be found on an instruction
plate on the inside of the burner door.
Boiler
This appliance is fitted with an automatic ignition unit that
will light the main burner on demand. Should button (K)
(see Fig. 1) be illuminated press button, this will allow the
burner ignition to continue, should the burner illuminate
again this will indicate a fault on the boiler burner, Contact
your local Gas Safe Registered engineer to correct the
fault.
Cooker (See Fig. 1)
Turn on gas cock (E).
Press in and hold the cooker flame failure override button
(C) allowing a few seconds for the gas to reach the cooker
pilot.
Press the piezo ignitor button (D) and the pilot burner will
light.
Continue to hold the button for 15 seconds after the pilot
has been lit so that when the button is released, the pilot
should remain alight. If it does not, WAIT 3 MINUTES then
repeat the procedure.
Ensure the electricity supply is turned ON and set any
external controls to the ON position.
Turn the boiler thermostat knob to ‘MAX’, and the boiler
burner will light to full rate.
Turn the cooker thermostat knob to ‘H’, and the cooker
burner will cross light to full rate.
NOTE: SMOKE/SMELL EMITTED DURING INITIAL
USAGE
Some parts of the cooker have been coated with a light
coating of protective oil. During initial operation of the
cooker, this may cause smoke/smell to be emitted and is
normal and not a fault with the appliance, it is therefore
advisable to open doors and or windows to allow for
ventilation. Lift the lids to prevent staining the linings.
INSTRUCTIONS
4
FIG. 1
DESN 512964
C - COOKER FLAME FAILURE OVERRIDE
BUTTON
D - PIEZO IGNITION BUTTON - COOKER
E - GAS COCK - COOKER
G - GAS COCK - BOILER
K - BOILER BURNER RESET